2

Signet 8150 Flow Totalizer

Caution / Warning / Danger

Indicates a potential hazard. Failure to follow all warnings 

may lead to equipment damage, injury, or death

Electrostatic Discharge (ESD) / Electrocution Danger

Alerts user to risk of potential damage to product by ESD,  

and/or risk of potential of injury or death via electrocution.

Hand tighten only!

Hand Tighten Only

Overtightening may permanently damage product threads 

and lead to failure of the retaining nut.

Do Not Use Tools

Use of tool(s) may damage product beyond repair and 

potentially void product warranty.

Dimensions

Refer to your local Georg Fischer Sales office for the most 

current warranty statement.
All warranty and non-warranty repairs being returned must 

include a fully completed Service Form and goods must be 

returned to your local GF Sales office or distributor.  

Product returned without a Service Form may not be  

warranty replaced or repaired.
Signet products with limited shelf-life (e.g. pH, ORP, chlorine 

electrodes, calibration solutions; e.g. pH buffers, turbidity 

standards or other solutions) are warranted out of box but not 

warranted against any damage, due to process or application 

failures (e.g. high temperature, chemical poisoning, dry-out) or 

mishandling (e.g. broken glass, damaged membrane, freezing 

and/or extreme temperatures).

Thank you for purchasing the Signet line of Georg Fischer 

measurement products.
If you would like to register your product(s), you can now 
register online in one of the following ways:
  •   Visit our website 

www.gfsignet.com.  

Under 

Service and Support

 click on  

Product Registration Form

  •  If this is a pdf manual (digital copy), 

click here

Chemical Compatibility

Warranty Information

Product Registration

Safety Information

 Integral Mount

96 mm

(3.8 in.)

96 mm

(3.8 in.)

FRONT VIEW

106 mm

(4.2 in.) 

82 mm

(3.2 in.)

Universal Mount

92 mm

(3.6 in.)

97 mm

(3.8 in.)

56 mm

(2.2 in.)

41 mm 

(1.6 in.)

Optional

Rear

Cover

Panel Mount

SIDE VIEW

102 mm

(4.0 in.)

42 mm 
(1.7 in.)

60 mm 
(2.3 in.)

96 mm

(3.8 in.)

The retaining nuts of paddlewheel sensors are not designed 

for prolonged contact with aggressive substances. Strong 

acids, caustic substances and solvents or their vapor may 

lead to failure of the retaining nut, ejection of the sensor and 

loss of the process fluid with possibly serious consequences, 

such as damage to equipment and serious personal injury. 

Retaining nuts that may have been in contact with such 

substances, e.g., due to leakage or spilling, must be replaced.

 Integral Mount

96 mm

(3.8 in.)

96 mm

(3.8 in.)

FRONT VIEW

106 mm

(4.2 in.) 

82 mm

(3.2 in.)

Universal Mount

92 mm

(3.6 in.)

97 mm

(3.8 in.)

56 mm

(2.2 in.)

41 mm 

(1.6 in.)

Optional

Rear

Cover

Panel Mount

SIDE VIEW

102 mm

(4.0 in.)

42 mm 
(1.7 in.)

60 mm 
(2.3 in.)

96 mm

(3.8 in.)

Содержание Signet 8150

Страница 1: ...150 Flow Totalizer is a battery powered instrument capable of providing uninterrupted flow and total volume information for 4 years and beyond The unique features of the 8150 include Easy setup and di...

Страница 2: ...mical poisoning dry out or mishandling e g broken glass damaged membrane freezing and or extreme temperatures Thank you for purchasing the Signet line of Georg Fischer measurement products If you woul...

Страница 3: ...umidity 0 to 95 non condensing Rating NEMA 4X IP65 front panel Shipping Weight 0 5 kg 1 1 lbs Quality Standards CE CUL UL Manufactured under ISO 9001 for Quality ISO 14001 for Environmental Management...

Страница 4: ...ng it so the square tab is close to the conduit ports 3 Insert the mounting screw into the conduit base so the head of the screw presses down on the locking ring when tightened 4 Connect sensor wires...

Страница 5: ...ied in bold type are required for the installation Other parts are shown for reference only Use 2 conductor shielded cable no more than 30 m 100 ft long Remote Field mount on Pipe Flow Totalizer 3 815...

Страница 6: ...d 6 Ext Reset Two 3 6 V lithium thionyl chloride batteries AA size 7400 0011 are installed in the Totalizer NOTE The 8150 will not operate with standard 1 5 V alkaline batteries USE 3 6 V SAFT LS14500...

Страница 7: ...uring normal operation Illustrated No flow for 3 hours Operation Standard Menu Settings ENTER 5 sec Function Factory set Description AUTO CALIBRATION No setting See page 11 for detailed information FL...

Страница 8: ...lement to the last digit 6 Press the key one time to scroll the flashing digit to 1 7 Press the ENTER key to complete the edit process 8 Press the and keys together to exit the Calibrate menu store th...

Страница 9: ...rge volume Total 2 tot2 can be reset only by entering the security code in the calibration menu Total 2 is identified by a flashing display every six seconds Application Use Total 2 for extended measu...

Страница 10: ...lizer value will begin flashing The totalizer will automatically reset to 00000000 in 8 seconds While the display is flashing you can cancel the reset by pressing and keys together 5 Press and keys to...

Страница 11: ...ted K Factor is less than 0 001 or greater than 999999 Verify the flow rate and start the AutoCAL procedure from step 1 8 Press and keys together to store the new value in the memory The display will...

Страница 12: ...o the decimal point 5 Press the key one time to move the decimal point one position to the right 6 Press the ENTER key to return to the menu 7 Press and keys together to exit the menu and return to no...

Страница 13: ...ay will not auto range If the decimal is set to tenths the flow rate display will show tenths up to 999 9 then the auto range will switch to whole numbers 1000 to 9999 If the decimal is set to hundred...

Страница 14: ...bilized but a sharp change in flow rate is not represented for 60 seconds or longer dotted green line With SPEED at 60 seconds and SENSITIVITY set to 6 the flow rate is stabilized while the sudden shi...

Страница 15: ...ss the ENTER key to return to the menu 6 Press and keys together to exit the menu and return to normal operation The display shows Storing for a few seconds then returns to the normal operating displa...

Страница 16: ...4 IR4T012 62 979 16 639 1 1 2 IR4T015 46 688 12 335 2 IR4T020 29 459 7 7832 BRONZE TEES ON SCH 40 PIPE 1 BR4T010 104 54 27 619 1 1 4 BR4T012 62 979 16 639 1 1 2 BR4T015 46 688 12 335 2 BR4T020 29 459...

Страница 17: ...950 DN 40 SFMT015 43 490 11 490 DN 50 SFMT020 25 908 6 8450 DN 65 SFMT025 18 067 4 7732 DN 80 SFMT030 12 357 3 2648 DN 100 SFMT040 8 0599 2 1294 DN 125 SFMT050 4 4312 1 1707 DN 150 SFMT060 3 2271 0 8...

Страница 18: ...ceiving a signal from the flow sensor 1 There is no flow in the pipe 2 Flow sensor is not turning due to blockage or damage 3 Sensor wiring is loose or incorrect In AutoCal the calculated K Factor is...

Страница 19: ...19 Signet 8150 Flow Totalizer Notes...

Страница 20: ...roof rear cover for panel mount totalizer 3 9000 392 159 000 368 Liquid tight connector kit includes 3 connectors 3 9000 392 1 159 000 839 Liquid tight connector NPT 1 connector 3 9000 392 2 159 000 8...

Отзывы: