3
Signet 8150 Flow Totalizer
Specifications
General
Compatibility ...................... Signet 515, 525 Flow Sensors
Input Frequency Range ..... 1 to 400 Hz
Accuracy ............................ ±0.5% of reading
Enclosure
Dimensions ........................ 1/4 DIN (96 mm × 96 mm × 50 mm)
(3.8 in. × 3.8 in. × 2.0 in.)
Case material .................... PBT resin
Keypad material................. Sealed 4-key silicon rubber
Display: LCD type
4-digit upper line ................ Flow rate
8-digit lower line................. Three totalizer options:
Permanent Totalizer ....... for life of instrument
Totalizer 1 ...................... resettable from keypad or remote
30 m (100 ft)
Totalizer 2 ...................... Resettable with security code only
Display Contrast ................ Automatic
Electrical
Battery ............................... Two 3.6 V lithium thionyl chloride,
AA-size (Use SAFT LS14500
Lithium Batteries or Equivalent Only)
Sensor power output ......... +3.6 VDC @ 20 µA
Battery life.......................... 4 years nominal @ 50 °C (122 °F)
Low Battery indication ....... Battery symbol on LCD display
Environmental
Operating Temperature ...... -10 °C to 65 °C (14 °F to 149 °F)
Storage Temperature ......... -40 °C to 100 °C (-40 °F to 212 °F)
Relative Humidity .............. 0 to 95%, non-condensing
Rating ................................ NEMA 4X/IP65 (front panel)
Shipping Weight
.............. 0.5 kg (1.1 lbs.)
Quality Standards
CE, CUL, UL
Manufactured under ISO 9001 for Quality, ISO 14001 for
Environmental Management and OHSAS 18001 for
occupational health and safety.
China RoHS (Go to www.gfsignet.com for details)
Declaration of Conformity according to FCC Part 15
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and,
(2) This device must accept any interference received,
including interference that may cause undesired operation.
Panel cutout
92 x 92 mm
(3.62 x 3.62 in.)
Output -
System Pwr
Loop -
System Pwr
Loop +
2
1
4
3
Sensr Gnd
(SHIELD)
Sensr IN
(RED)
Sensr V+
(BLACK)
7
6
5
quick-clips
gasket
panel
terminals
mounting
bracket
latch
Panel Mount
Installation Detail
The 8150-1P panel mount Totalizer is a standard ¼ DIN
package. Use a 92 × 92 mm punch tool to make the
panel cutout.
Minimum spacing of 25 mm (1 in.) between panel units is
recommended.
Panel Mount Installation Detail
Installation
Panel Cutout
Panel Mount
Installation Detail
Содержание Signet 8150