10 Fusion Machine Assembly
Instruction Manual BCF Plus
(11.15) BCF Plus_BA_04
14
10.3 Power
supply
The BCF Plus fusion machine will be connected directly via a 3-channel
115 V / 230 V- CE- shockproof plug to mains supply.
If the supplied mains plug needs to be exchanged because of the country-
specific electric power supply or connections, it is absolutely necessary that the
grounding is connected or the machine is grounded in some other way.
Wiring diagram 115 V / 230 V- CE:
L1:
Connect phases
N:
Connect
neutral
PE:
Connect grounding
For damages resulting from nonobservance of these instructions or from
negligence, the manufacturer assumes no liability. The operator of the fusion
machine bears sole responsibility.
For IT mains supply (IT= Isolated Terra) the customer must supervise the
isolation.
Excess voltage from the use of generators should be avoided.
Constant overvoltage and high voltage peaks can damage the electronic
system.
If using extension cables observe the following:
Cable cross-section: 115 V / 230 V min. 3 x 2.5 mm
2
max. cable length:
50m
Always fully unwind cable drums.
black
blue
green / yellow
L1
N
PE
L1
N
PE
NOTE