29
29
GEViCAM Inc
•
Including Delayer:
We can add delays into the trigger pulse
after sending Set value command (Fig. 49).
Let’s describe the PLC signal pass.
PLC_CTRL0 I1 Q3 Delayer I4
Pulse Gen#1
Q9 Pulse Gen#0 I0 Q0
For Signal Routing Block (Fig. 50)
I0: Pulse Generator 0 Output
I1: PLC Control Bit 0
I4:
Delayer
0
Output
Delayer 0 (Fig. 51)
Delay count: 30 (60 ms x 30 = 1.8 s)
Input
signal:
Q3
Reference timing: Pulse Generator 1 output
Pulse
Generator
0
Same as Fig. 47
Pulse Generator 1 (Fig. 51 & 52)
Width: 1024 (30 ms)
Delay: 1024 (30 ms)
Granularity:
1000
(30
µ
s)
Periodic : Yes (marked)
Lookup Table (Fig. 50)
Q0=I0
Q3=I1
Q9=I4
In this practice, you will see the delayed pulse by
roughly 2 seconds generated after you click
“PLC_CTRL0” pane. By changing Width bar at “Pulse
Generator #0”, you will see the brightness changes
and by changing the values of “Pulse Generator #1”,
Fig. 49
Fig. 50
Fig. 51
Fig. 52