D
UA
TR
CZ
SK
SLO
RO
P
P
L
LT
LV
EST
GR
RUS
FIN
DK
S
E
I
N
L
F
GB
H
Colour surveillance system CSS
Control elements
Monitor (fi g. A)
1 Camera 1 switch
2 Automatic
camera
change
3 Camera 2 switch
4 ON/OFF
switch
5 Camera switch interval: setting 5 - 50 seconds
6 Volume
7 Camera 1 connection socket
8 Camera 2 connection socket
9 Power supply 12 V = connection socket
10 Attachment wall holder/table stand
11 Loudspeaker
12 Wall holder
13 Table stand
Camera (fi g. B)
1 Camera lens
2 IR LEDs
3 Microphone
4 Wall holder
5 Cable 18 m
6 Plug
Power supply (fi g. C)
Safety information
All warranty claims will be null and void in the
event of any damage or loss caused by failure
to observe these operating instructions.
We accept no liability for any consequential
losses or damage. We accept no liability for any
personal injury or material damage caused by improper
use or by failure to observe the safety advice. In these
cases the guarantee and warranty are invalidated. For
safety and authorisation purposes it is not permitted to
carry out any adaptation or conversion of the device.
Mounting
If you are unsure of how to assemble, connect and
install the device or if you are in doubt as to how to
operate it, please do not assemble, connect or install
the device yourself but contact a qualifi ed specialist.
Please observe the position of the camera when
mounting as shown in
fi g. D
and mount so that it is not
exposed to direct environmental effects such as rain.
The microphone opening
B3
must face down.
The monitor can either be attached to the wall
(fi g. E1)
using wall holder
A12
or placed on a table top
(fi g. E2)
using table stand
A13
. Clip the wall holder or table
stand into the appropriate attachment
A10
on the
monitor in the selected position.
Connection (fi g. F)
Connect plug
B6
from the fi rst camera into connection
socket camera 1
(A7)
on the monitor. You have the
option of connecting a second camera (not supplied)
to camera 2 connection socket
(A8)
. Connect the
power supply plug
(fi g. C)
to connection
A9
and insert
the plug into the appropriate socket. Only use GEV
system cameras, as cameras/devices from other
suppliers may damage the colour surveillance system
CSS.
Starting up/operating
Press the
ON/OFF
key
(A4)
. The LED in the key lights
up if there is mains power and the monitor displays the
image from camera 1.
The volume is adjusted using the
loudspeaker
controller
(A6)
. Direct the camera as required.
If a second camera is also connected, press the
Camera 2 (A3)
key and set as required. The images
from cameras 1 and 2 can be shown in sequence.
Press the
automatic camera switch
key
(A2)
. The
interval can be infi nitely adjusted from 5 - 50 sec.
using the
switch interval
controller
(A5)
. An LED
is integrated into keys
A1, A2, A3 and A4
to
indicate the settings.
The cameras are fi tted with IR LEDs to allow persons
and objects to be identifi
ed within a range of
approx. 1 m, even in the dark (for technical reasons
these images are only available in black and white).
Optional accessories
Heated camera (art. no. 085091)
In cold regions it is necessary to use a heated camera.
This is designed for external temperatures down to
-25 °C.
The supplied 1000 mA wall power supply must be
replaced with a 2000 mA wall power supply (art. no.
085138). This allows up to 2 heated cameras (art. no.
085091) to be connected to the monitor.
Insert the plug
B6
from the camera into the connection
socket of camera 1 or 2
(A7 or A8)
. This works in
exactly the same way as the standard camera.
Troubleshooting – practical tips
Problem Cause
Solution
No picture and ON/OFF
Is the wall power supply connected?
Connect wall power supply
LED does not light up
No picture and ON/OFF
Wall power supply is faulty/
Take wall power supply/monitor for
LED does not light up
monitor is faulty
inspection if necessary
No picture/faulty picture
Is the camera connected?
Check plug
Is the camera cable damaged?
Check and if necessary replace
cable
Camera is faulty
Check and if necessary replace
camera
Picture rotated by 180°
Camera has been mounted upside
Mount camera with the
down
microphone facing down
Picture is black and white
Night image, caused by IR LEDs
Normal for night time surveillance
Whistling sound
Camera is too close to monitor
Reposition camera
No sound/sound too quiet
Volume is set too low
Set the volume
No sound
Is the camera cable damaged?
Check and if necessary replace
cable
Camera microphone is faulty
Check and if necessary replace
camera
Technical data
Monitor
Dimensions
approx. W 120 mm x H 126 mm x D 32 mm
Display type
TFT 3.5 inch (visible diagonal measurement 87 mm)
Resolution
480 x 234 pixels
Voltage 12
V
=
Standby mode power consumption
approx. 1.0 mA
Operating power consumption
approx. 180 mA
Operating temperature range
-10 °C to +45 °C
Camera
Dimensions
approx. W 57 mm x H 80 mm x D 70 mm
Camera module
CMOS 1/3 inch
Resolution
628 x 582 pixels
Exposure time
automatic 1/60 to 1/15000 sec.
Min. lighting
< 3 Lux (at a distance of < 50 cm)
Operating voltage (supplied by monitor)
8 - 13 V =
Operating power consumption
approx. 70 - 100 mA
Operating temperature range
-10 °C to +45 °C
Max. cable length
approx. 72 m
Protection type
IP 44
Power supply
Test symbol
TÜV LGA/GS
We reserve the right to make technical and visual modifi cations without prior notice.
Gutkes GmbH
Postfach 730 308
Fax: +49 (0)511 / 958 58 05
30552 Hannover
Internet: www.gev.de
Germany E-Mail:
MA CSS85008 INTERNET.indd 7-8
MA CSS85008 INTERNET.indd 7-8
22.02.2007 9:22:20 Uhr
22.02.2007 9:22:20 Uhr