Maintenance
59
To replace the fuse
WARNING: Turn off power at the plotter and the system and
disconnect the power cord from the power supply.
1. Unscrew and remove the RS-232 cable from the rear panel of
the HS750
plus
.
2. Remove the plotter power cord from the socket.
3. Find the small notch at the right edge of the black plastic plate
on the rear panel. Insert a flat-tip screwdriver into the notch
and flip the black plastic plate open.
z
4. Pull out the light gray fuse carriers one at a time. Note that
each carrier has a white arrow on it and that the arrow points
downward (as do the two arrows on the black plastic plate).
5. Examine each fuse. Remove any blown fuse. Install a new
fuse of the same type and rating in the same place.
6. Reinsert each carrier, with the arrow pointing downward. Be
sure that the carriers are inserted all the way. Close the black
plastic plate firmly.
7. Reinstall the power cord and the cable connector. Turn the
power on at the system and at the plotter.