Prepare two plot files. If using OMEGA to prepare the files, in the
Plot Program choose a left Start Position and a right End Position for
both plots before sending them to the plotter. This will prevent the files
from plotting on top of each other. If using another layout program, be
sure to position the files so they will not plot on top of each other.
Note: Entering an X,Y pre-position in the Plot Program is another way to be
sure that plots done in the RUN CONT mode will not plot on top of each other.
(See
OMEGA Reference
.)
4
Press the RUN CONT key. Both jobs will plot without a pause between
them.
reset
Use the RESET key to stop plotter operation in case of emergency,
to clear error signals, and to access Special Diagnostics.
RESET
To cause an emergency stop
Press the RESET key while a job is plotting. The following sequence occurs:
1
GSx
plus
operation stops immediately.
2
The current job is cleared. All other jobs in the queue remain intact.
3
The GSx
plus
returns to off-line status, as at power-up.
To clear an error signal
Press the RESET key to clear an error signal (steady tone and flashing lights)
after a power-up or plotting failure. (See the "Error Conditions" section.)
To access diagnostics
Hold the RESET key at power-up to access additional diagnostics. (See the
"Special Diagnostics" section.)