SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual
Last Updated August 2018
18
Download Port:
When connecting to the controller using TCP/IP, this specifies the IP port to use. By
default this is port 21000.
Download Server
: Defines the download server used by the controller.
Control and Status Request Port
: The IP port through which control commands will be sent. By default
this is port 21001.
Last Known IP Address
: Shows the last IP address that the controller communicated to the server on.
(Read only)
Last Downloaded
: Shows the date and time of the last download. (Read only)
Display
Panel Name:
The name used to identify the Controller in the IP reporting services.
Controllers | Configuration Settings
Configuration
Test Report Time (HH:MM):
The test report time, in conjunction with the
Test Report Time is Periodic
option, sets the time of the day or the period that the test report trouble input activates. When the
Test
Report Time is Periodic option
is enabled, the time programmed will be used as a period between
reports in hours and minutes, else it is treated as a time of day.
Automatic Offline Time
: Allows the panel to update the users and other offline parameters on all
intelligent modules at a set time of the day.
AC Restore Delay Time (seconds):
The AC Restore time allows the installer to program a time that AC
must be present for after a AC Failure before restoring the AC Failure Trouble Input. Set this to a larger
value for locations that experience frequent but short interruptions in power or that operates on a
generator frequently. This setting is only relevant to older hardware which is supplied by an AC power
source.
AC Fail Time (Seconds):
The AC Failure time allows the installer to program a time that AC mains
voltage must have failed before activating the AC Failure Trouble Input. Set this to a larger value for
locations that experience frequent but short interruptions in power or that operates on a generator
frequently. This setting is only relevant to older hardware which is supplied by an AC power source.
Module UDP Port:
This is the UDP port that all Ethernet enabled modules will communicate with the
Synergis controller over. If this port is changed all modules will also need to be changed.
Modem Country:
The onboard modem must be configured for the region that the controller is being
installed in to ensure proper operation.
Modem Backup Phone Number
: If Ethernet communication fails, the modem will dial this number to
report events.
Default Language:
The controller supports multiple languages on the keypad and the serial event
printers. The language selected here will be the default language for users who have no language
selected and also for any events.
Download Retry Delay
: Defines the frequency (in seconds) at which the software sends programming
updates to the controller.
Register as Reader Expander
: Used for programming the onboard reader. The onboard reader is
programmed as and treated by the system as if it were a reader expander connected on the module
network. This setting defines the address at which the onboard reader will be registered and must be
distinct from any physical reader expanders connected to the module network.
Onboard Reader Lock Outputs
: Defines the output that will be activated upon successful door access. If
set to none, the lock output (if any) programmed under the associated reader expander will be used.
Touchscreen UDP Port
: The UDP port that a touchscreen will communicate over.