SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual
Last Updated August 2018
26
Inputs
The Controller has 2 onboard inputs for monitoring the state of devices such as magnetic contacts, motion
detectors and temperature sensors. Devices connected to these inputs can be installed to a maximum
distance of 300m (1000ft) from the Controller when using 22 AWG.
Inputs can be programmed. Inputs CP001:01 and CP001:02 represent the Controller's onboard inputs.
Additional inputs are supported through the use of expansion modules.
The Controller supports normally opened and normally closed configurations with or without EOL resistors.
When using an input with the EOL resistor configuration, the Controller generates an alarm condition when the
state of an input is toggled and generates a tamper alarm condition when a wire fault (short circuit) or a cut
(tampered) in the line occurs. Inputs default to require the EOL resistor configuration.
EOL Resistor Input Configuration:
N.C Input Contact
N.C Tamper
1K
1K
Z2
V-
Z1
NC
C
NO
ZONE 2
ZONE 1
R
ELA
Y
1
Inputs 1 and 2 can operate as either general purpose inputs or as onboard reader inputs. If used as general
purpose inputs you must ensure that they are not defined in the onboard reader set up.
Each input can use a different configuration. To program a large number of inputs with a certain configuration,
use the multiple selection feature within the Synergis user interface.
When using the No Resistor configuration, the Controller only monitors the opened and closed state of the
connected input device generating the alarm and seal conditions.
No EOL Resistor Input Configuration:
N.C Input Contact
Z2
V-
Z1
NC
C
NO
ZONE 2
ZONE 1
R
ELA
Y
1