SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual
Last Updated August 2018
9
Connections
Power Requirements
Power is supplied to the Controller by a 12V DC power supply connected to the N+ and N- terminals. The
Controller does not contain internal regulation or isolation and any clean 12V DC supply is suitable for this
purpose.
Warning:
Termination of wiring to the Controller while power is applied or the battery is connected
may cause serious damage to the unit and will VOID ALL WARRANTIES OR GUARANTEES.
Power the unit only after all wiring, configuration and jumper settings are completed.
A battery backup must be connected to the module network to provide a monitored supply. The battery plays
an important role in power conditioning and provides a continuous source of power in the event of a power
outage.
Example 2A Power Supply Connection:
Controller
Power Supply
NA
N+
N-
NB
+
-
To other modules
on network
Mains Input
NA
N+
N-
NB
AC AC
B+
B-
V1-
V2+ V-
V-
Transformer
Gel Cell Backup Batteries
+
-