TROUBLESHOOTING
5 -2
96622 Issue 4.0 Jan 01
In the event there is a problem that is not covered in the following chart, call
your local representative
.
Symptom
Probable Cause
Remedy
No Display on Print
Station LCD
No AC. Power
Check plug to outlet.
No Display on
Controller’s LCD
No power in the
batteries.
Replace/check batteries.
Print Station will
not Print
No message stored
in Controller.
Query Print Station and re-
enter message.
Incorrect
parameters.
Query Print Station and verify
parameters.
Poor Print Quality
Print head dirty or
clogged.
Refer to Part 4 for cleaning the
print head.
Bad array plate.
Refer to Part 4 for replacing
the array plate.
Incorrect cartridge
height adjustment.
Refer to Part 2 for setting
cartridge height.
Excessive vibration. Refer to Part 2 about correct
installation location.
Print head too far
from product.
Refer to Part 2 for correct
distance between print head
and product.
Dirty or clogged
screen.
Clean; replace print head
components.
Presence of Satellite
Dots
Dot intensity too
high.
Refer to Part 3 for adjusting
dot intensity.
Print Head too Low. Refer to Part 2 for adjusting
Print Head height.