Operation Manual for ZBL-R620/R630 Rebar Locator
Place the probe in the correct direction (with the ports of the probe and Scan Car in
same direction, see fig 2.3), the central hole of the probe must be aligned with the raised
point on the scan car. The probe should click firming and tightly into place.
Caution: When removing the probe from the scan car, open the two red clips and push the
probe out.
2.2 Startup
Press the power On/Off key “
” and the rebar locator begins to operate.
The screen displays the startup interface (Fig. 2.4):
The displayed information is as follows:
-
Name of the Company
-
Name and model number of the Rebar Locator
-
Version Number of Rebar locator
-
Remaining battery life
-
Todays date
When the remaining power of the battery is low, the bar flashes three times, and there is
a short beeping sound, indicating that the battery must be re-charged.
If the automatic self-test is OK, it automatically enters the menu display after about five
seconds.
Shortcuts in Main Menu interface:
【→
→
→
→】
key, background light on/off switch;
【↑
,
↓】
keys, move cursor up or down;
【
Enter
】
key, access the highlighted option
2.3 System Reset
The reset operation is used to elimination instrument interference coming from
environmental factors, and ensures that the test results are accurate and reliable. Before
implementing a reset operation hold the transducer in the air, away from magnetic
materials, and then begin the reset operation as detailed below. After 3 seconds, the
current thickness value displays as “0” to indicate that the reset is complete, the display
will then access “test waiting” status.
The system reset can be operated by the following two methods
1) Auto reset – when instrument accesses scan interface an automatic reset operation is
implemented.
2) Manual reset – press
【
Enter
】
key when in scan-test interface, to implement reset
operation.
Fig. 2.3 Attach and remove
Fig. 2.4 Startup Display