60
NO-LOAD PERFORMANCE
z
Disconnect the magneto lead wire coupler.
z
Start the engine and keep it running at 5000r/min.
z
Using a pocket tester, measure the AC voltage between the white and red tracer
lead wire and ground. If the tester reading is as follows, magneto is in good
condition.
Standard no-load performance: more than
65v(AC)AT 5000R/MIN.
STATOR COILS
Inducing coils
Use procket tester to measure the resistance
between the lead wire and ground. If the resistance
checked is not correct, replace the coil.
Rregulator/rectifier
Disconnect the lead wire couple.
Using the pocket tester
(
× 1KQ RANGE
)
, measurethe resistance between the
terminals as shown in the following table. If the resitance checked is incorrect, replace
the regulator/rectifier.
UNIT:
NOTES
:
Including the components such as
transistor,capacitance, regulator
diode and so on, so tested
resistance may be different from
actual resistance.
Standard
resistance
W/R-GROUND 0.6-1.1Q
W/R-GROUND 0.5-0.8
Q
Содержание XOR 50 ccm
Страница 1: ......
Страница 19: ...19 14...
Страница 42: ...42 z install the bearing in the fixed driven face with the special tool z install sliding bearing...
Страница 52: ...52 CHAPTER 4 FUEL AND LUBRICATION SYSTEM CONTENTS FUEL SWITCH CARBURETOR OIL PUMP...
Страница 73: ...73 3 Disconnect throttle cable and oil pump cable 4 Remove rear brake cable adjusting nut...
Страница 86: ...86...
Страница 101: ...101 WIRE CABLE AND BRAKE HOSE ROUTING...
Страница 102: ...102 carburetor...
Страница 103: ...103...
Страница 104: ...104 Ignition coil Starting relay CDI HORN POWER SWITCHH...
Страница 106: ...106...