AT Command Set Operation
AT Command Reference Tables
4-12
SpectraComm Dual V.34 Modem
060R122-000
Installation and Operation
Issue 15
O
n
On-line
Instructs the modem to go on-line (enter data mode) after an escape to local
command mode is issued. This command transfers the modem from command mode
to data mode.
O0
Instructs the modem to go on-line.
O1
Instructs the modem to go on-line and issue a retrain sequence if operating in V.34,
V.22 bis, V32, or V32 bis modes.
%O
n
Answer mode
For a modem on a switched network this command selects the band the modem will
use for both automatically and manually answered calls. For a modem on a private
line, this command selects the band the modem will use for connections.
%O0
Commands the modem, in switched network mode, to use the presence of a ring to
determine the band, regardless if automatic answer is selected. In private line mode,
the modem will be in the originate band.
%O1
Commands the modem to answer calls in the answer band in either switched network
or private line mode.
%O2
Commands the modem to answer calls in the originate band in either switched
network or private line mode.
P
Dialing type
Instructs the modem to use pulse dialing. The command may be used alone or as
part of a dial string. When
P
is used alone, it makes pulse dialing the modem's
default dialing method. When
P
is used in a dial string, it acts as a modifier and
affects only the dialing of that string. Pulse dialing is blocked by some country code
configurations.
&P
n
Private line handshake
mode
Controls the selection of the private line handshake mode.
&P0
Selects V.34 only (28.8 - 2400)
&P1
Selects V.32 bis only (14.4 - 4800)
&P2
Selects V.32 only (9600 and 4800)
&P3
Selects IUT-T 212 (1200)
&P4
Selects IUT-T 103 (300)
%P
n
=
nnn
Store password
Stores passwords in the modem’s 10 memory cells, where
n
= 0 - 9 and
nnn
= a
password of up to 10 characters. To disable or clear a cell password, type
%P
n
=
<cr>
. This command is not affected by factory defaults.
%P0=
nnn
When configured for SteadFast Security, cell 0 must be used for the SteadFast
password.
\P
n
Parity type
Sets up what parity to use in data mode for front ends that do not send AT
commands.
\P0
Even parity
\P1
Space parity
\P2
Odd parity
\P3
Mark parity
\P4
Automatic parity; last AT (default)
:P
n
Switched network
transmit type
Selects permissive or programmable mode for switched network operation.
:P0
Selects permissive mode.
:P1
Selects programmable mode.
*P
n
Remote configuration
security password
Defines the remote configuration security password, where n = a password of 1 to 11
characters. To disable or clear the password, enter
*P
.