10
Installation Manual for Generac PWRcell Battery
General Information
Component Locations
ON
OFF
BATTERY DISCONNECT
0009890
C
D
E
B
A
Figure 2-4. Component Locations
A
Battery Disconnect Switch
B
Battery Status LED
C
Intake Filter
D
Front Cover
E
Exhaust Vent
Battery Disconnect Switch
(000600)
DANGER
Electrocution. Initiate a system-wide safety shutdown
and turn PWRcell Disconnect Switch OFF on all
connected batteries before performing service. Failure
to do so will result in death, serious injury, equipment
and property damage.
See
. Battery Disconnect switch (A)
disconnects the battery string from the battery monitoring
system (BMS) electronics.
NOTE:
Battery Disconnect can be locked in the OFF
position if required.
NOTE:
Turn Battery Disconnect OFF whenever system
will be powered down and left inactive for an extended
period of time.
Battery Status LED
See
The color and strobing interval of LED
(B) communicates the Generac PWRcell Battery status.
Table 2-1. Battery Status LED
LED State
Interpretation (strobe interval)
Green, 3 sec
solid at power up
Enabled, operation starting
Red, 3 sec solid
at power up
Disabled
Red/green,
alternating
Initializing, connecting battery and
REbus, system energizing
Green, solid
Enabled, charging
Green, strobe
Enabled, standby (3 sec)
Green, flashing
Enabled, discharging
Orange, solid
Waiting
Orange, strobe
Asleep (8 sec)
Red, strobe
Disabled (3 sec)
Red, flashing
Error state