Generac Power Systems IX 1400 Скачать руководство пользователя страница 9

 

 

7

*Garage Door Opener. . . . . . . . . . . . . . . . . . . . . . . . . . .  500 to 750
Hair Dryer  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
Hand Drill. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  250 to 1100
Hedge Trimmer  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 450
Impact Wrench  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500
Iron  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
*Jet Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 800
Lawn Mower  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
Light Bulb  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Microwave Oven  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  700 to 1000
*Milk Cooler  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1100
Oil Burner on Furnace. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300
Oil Fired Space Heater (140,000 Btu) . . . . . . . . . . . . . . . . . . . . . 400
Oil Fired Space Heater (85,000 Btu) . . . . . . . . . . . . . . . . . . . . . . 225
Oil Fired Space Heater (30,000 Btu) . . . . . . . . . . . . . . . . . . . . . . 150
*Paint Sprayer, Airless (1/3 HP) . . . . . . . . . . . . . . . . . . . . . . . . . 600
Paint Sprayer, Airless (handheld)  . . . . . . . . . . . . . . . . . . . . . . . . 150
Radio. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  50 to 200
*Refrigerator  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700
Slow Cooker  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
*Submersible Pump (1-1/2 HP) . . . . . . . . . . . . . . . . . . . . . . . . 2800
*Submersible Pump (1 HP)  . . . . . . . . . . . . . . . . . . . . . . . . . . . 2000
*Submersible Pump (1/2 HP). . . . . . . . . . . . . . . . . . . . . . . . . . 1500
*Sump Pump. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  800 to 1050

* Allow three (3) times the listed running watts for starting theses devices.

NOTE:

When an electric motor is started, the "OVERLOAD" LED may 

light up for up to five (5) seconds (this is normal). If it stays on, 

a fault has occured. Remove all loads and shut down generator 

to reset the alarm. Restart the generator. If the "OVERLOAD" 

LED remains lit, contact a Generac Dealer for assistance.

USING THE FLEXPOWER™ SWITCH

When the accessories connected to the generator are going to 

be used intermittently (such as a hand drill), the FlexPower™ 

switch can be pushed to the “ON” (I) position.  This will lower the 

generator engine speed when loads are not being applied, saving 

fuel, reducing engine wear and extending runtime.

USING THE 12 VDC BATTERY CHARGER

The 12 VDC receptacle may be used to recharge 12 VDC 

automotive batteries only. The DC charging output is not regulated. 

The circuit protector does not prevent over-charging a battery.

1.  Connect the charging cable to the generator first, then the 

battery, ALWAYS connecting the red lead to positive (+) and 

the black to negative (-).

 Do not permit smoking, open flame, sparks 

or any other source of heat around a battery. 

Wear protective goggles, rubber apron 

and rubber gloves when working around 

a battery. Battery electrolyte fluid is an 

extremely corrosive sulfuric acid solution 

that can cause severe burns. If a spill occurs, 

flush area with clear water immediately.

 Storage batteries give off explosive hydrogen 

gas while recharging. An explosive mixture 

will remain around the battery for a long 

time after it has been charged. The slightest 

spark can ignite the hydrogen and cause an 

explosion. Such an explosion can shatter the 

battery and cause blindness or other serious 

injury.

 NEVER reverse the polarity when connecting 

the battery terminals to the charging jack. 

Severe damage may occur to the generator 

and battery.

2.  Keep the FlexPower™ switch in the “OFF” (O) position.
3.  Start the generator and use it as normal. Charging time will 

vary with battery size and condition.  Check the voltage at the 

battery terminals once the charging cable has been unplugged 

or the generator has been shut down.

NOTE:

This receptacle can not recharge 6-Volt batteries 

and can not be used to crank an engine having a 

discharged battery.

SHUTTING DOWN

Once the generator is no longer needed it can be shut down.

1.  Switch off any accessories connected to the generator. Unplug 

any cords to the 120 VAC duplex outlets or the 12 VDC plug.

2.  Turn the fuel valve to the “OFF” (O) position (Figure 7). A 

switch behind the fuel valve grounds the ignition system, 

stopping the engine and the fuel supply is shut off.

3.  Close the vent on the fuel cap.
4.  Allow the generator to cool before moving or storing.

 Always allow the generator to cool off before 

storing. High temperatures will be present 

at the rear of the unit for some time after 

shutdown.

Figure 7 - Turn Off Fuel

TURNING THE FUEL OFF

7

Operation

Содержание IX 1400

Страница 1: ...Inverter Generator Operator s Manual MODEL 005842 0 DEADLY EXHAUST FUMES ONLY use OUTSIDE far away from windows doors and vents NOT for use in critical life support applications SAVE this Manual Prov...

Страница 2: ...l Tank 8 Adding Engine Oil 8 To Add Engine Oil to the Crankcase 8 Maintenance 9 Generator Maintenance 9 Generator Maintenance Schedule 9 Cleaning the Generator 9 Engine Maintenance 10 Changing the Eng...

Страница 3: ...m carefully Their definitions are as follows Indicates a hazardous situation or action which if not avoided will result in death or serious injury Indicates a hazardous situation or action which if no...

Страница 4: ...cally conductive parts of the generator be properly connected to an approved earth ground Local electrical codes may also require proper grounding of the generator Consult with a local electrician for...

Страница 5: ...esource Council P O Box 309 Wilmington OH 45177 0309 5 ASAE EP 364 2 Installation and Maintenance of Farm Standby Electric Power available from www asabe org American Society of Agricultural Biologica...

Страница 6: ...trol system on your generator consists of the following Fuel System Air Induction System Fuel Tank Intake pipe manifold Fuel Cap Air cleaner Carburetor Ignition System Fuel Lines Spark plug Evaporativ...

Страница 7: ...rection non combustible surface with at least five 5 feet of clearance on all sides Never operate in an enclosed area or indoors NEVER use in the home in a vehicle or in partly enclosed areas such as...

Страница 8: ...rass etc as the cooling vents are located on the bottom of the unit Figure 5 Prime Fuel System FUEL SYSTEM VENT PLUNGER VENT Figure 6 Adjust Choke ENGINE CHOKE OPERATION ON I OFF O ADDING LOADS Once t...

Страница 9: ...not permit smoking open flame sparks or any other source of heat around a battery Wear protective goggles rubber apron and rubber gloves when working around a battery Battery electrolyte fluid is an e...

Страница 10: ...ays allow room for fuel expansion If tank is over filled fuel can overflow onto a hot engine and cause FIRE or an EXPLOSION Wipe up fuel spills immediately TO FILL THE FUEL TANK 1 Remove the fuel tank...

Страница 11: ...be retained in voids and crevices of the rotor and stator winding insulation Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these wind...

Страница 12: ...nge the engine oil after the first five 5 hours of operation Change the engine oil every 100 hours thereafter To change the engine oil Change the oil only when the fuel tank is low or nearly empty Tip...

Страница 13: ...an engine while in storage To avoid engine problems the use of a commercial fuel stabilizer prior to storage is recommended Follow the manufacturer s instructions when adding the fuel stabilizer If t...

Страница 14: ...e spark arrestor must be maintained in cood condition by the owner operator Clean and ispect the spark arrestor as follows Remove the screen retainer by removing the retainer clamp Slide the spark arr...

Страница 15: ...rk plug 4 Replace fuel filter 5 Replace FlexPower switch No AC output 1 Generator is overloaded OVERLOAD LED is on 2 AC voltage is low OVERLOAD LED is on 3 Inverter module is overheated OVERLOAD LED i...

Страница 16: ...14 Notes...

Страница 17: ...15 Notes...

Страница 18: ...coverage or responsibility if your equipment or a part component thereof has failed due to abuse neglect improper maintenance or unapproved modifications You are responsible for contacting a Generac A...

Страница 19: ...ntenance in the Owner s Manual shall be warranted for the period of time prior to first scheduled replacement point for that part If the part fails prior to the first scheduled replacement the part sh...

Страница 20: ...y any contaminated fuels oils or lack of proper oil levels Repairs or diagnostics performed by individuals other than Guardian Generac authorized dealers not authorized in writing by Generac Power Sys...

Страница 21: ...or Digital MODELO 005842 0 PELIGRO GASES DE ESCAPE MORTALES Util celo SOLAMENTE al AIRE LIBRE y lejos de ventanas puertas y respiraderos NO dise ado para uso en aplicaciones de soporte de vida cr tica...

Страница 22: ...agregar aceite al motor 8 Para a adir aceite de motor al c rter del motor 8 Mantenimiento 9 Mantenimiento del generador 9 Programa de mantenimiento del generador 9 Limpieza del generador 9 Mantenimie...

Страница 23: ...situaci n o acci n peligrosa que si no se evita puede ocasionar la muerte o una lesi n grave ADVERTENCIA Indica una situaci n o acci n peligrosa que si no se evita podr a ocasionar la muerte o una le...

Страница 24: ...El ctrico Nacional NEC requiere que el marco y las partes conductoras del exterior del generador est n conectadas correctamente a una tierra aprobada Los c digos el ctricos locales pueden tambi n requ...

Страница 25: ...on OH 45177 0309 5 ASAE EP 364 2 Instalaci n y mantenimiento de energ a el ctrica de respaldo en granjas disponible en www asabe org Sociedad Americana de Ingenieros Agr colas y Biol gicos2950 Niles R...

Страница 26: ...nsiste en lo siguiente Sistema de combustible Sistema de inducci n de aire Tanque de combustible Tuber a m ltiple de admisi n Tap n del combustible Limpiador de aire Carburador Sistema de ignici n L n...

Страница 27: ...en un veh culo o en el interior AUNQUE las puertas y ventanas est n abiertas selo S LO en exteriores y lejos de ventanas abiertas puertas ductos de ventilaci n y en reas que no acumular n el mortal ga...

Страница 28: ...los respiraderos de enfriamiento se localizan en la parte inferior de la unidad Figura 5 Cebado del sistema de combustible RESPIRADERO DE SISTEMA DE COMBUSTIBLE MBOLO RESPIRADERO Figura 6 Ajuste del a...

Страница 29: ...ositivo y el negro al negativo PELIGRO No permita fumar llamas abiertas chispas o ninguna otra fuente de calor alrededor de una bater a Use gafas protectoras delantal de hule y guantes de hule al trab...

Страница 30: ...LOSI N Limpie inmediatamente los derrames de combustible PARA LLENAR EL DEP SITO DE COMBUSTIBLE 1 Quite el tap n del dep sito de combustible 2 A ada el combustible lentamente dejando un espacio de dos...

Страница 31: ...devanado del rotor y del estator La acumulaci n de agua y suciedad en los devanados internos del generador disminuir eventualmente la resistencia del aislamiento de estos devanados PROGRAMA DE MANTEN...

Страница 32: ...inco 5 horas de operaci n Despu s cambie el aceite del motor cada 100 horas Para cambiar el aceite del motor CUIDADO Cambie el aceite solamente cuando el nivel de combustible en el dep sito est bajo o...

Страница 33: ...amiento Para evitar problemas del motor se recomienda el uso de un estabilizador comercialdecombustibleantesdelalmacenamiento Sigalasinstrucciones del fabricante al a adir el estabilizador de combusti...

Страница 34: ...chispas como sigue Retire el retenedor del filtro retirando la abrazadera del retenedor Deslice el filtro del supresor de chispas fuera del tubo de salida del silenciador Inspeccione el filtro y reem...

Страница 35: ...FlexPower No hay salida de CA 1 Generador sobrecargado la luz indicadora SOBRECARGA est encendida 2 Voltaje de CA bajo la luz indicadora SOBRECARGA est encendida 3 M dulo del inversor recalentado la l...

Страница 36: ...14 Notas...

Страница 37: ...15 Notas...

Страница 38: ...si su equipo o una parte o componente del mismo ha fallado debido al abuso mantenimiento inapropiado o modificaciones no autorizadas Usted es responsable de ponerse en contacto con un Centro de Garant...

Страница 39: ...e del mantenimiento necesario en el Manual del Usuario ser garantizada por el periodo de tiempo previo al primer remplazo programado para dicha pieza Si la pieza falla antes del primer reemplazo progr...

Страница 40: ...aminados o la falta de niveles apropiados Reparaciones o diagn sticos realizados por individuos diferentes a los concesionarios autorizados por Guardian Generac que no est n autorizados por escrito po...

Отзывы: