 4 

SPECIFICATIONS

Engine Type . . . . . . . . . . . . . . . . . . . . . . . . Single Cylinder, 4-Stroke

Engine Size  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80cc

Starter Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Recoil

Fuel Capacity/Type . . . . . . . . . . . . . . . . . 0.73 Gal (2.77 L)/Unleaded

Oil Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.63 Qt (0.6L)

Runtime Full/Half Load . . . . . . . . . . . . . . . . . . . . . . . . 2.5/5.0 Hours

Spark Plug Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  BPR7HS

Spark Plug Gap  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..030”

Dimensions L x W x H (in)  . . . . . . . . . . . . . . . . . . . . . . 22 x 12 x 18

Weight Lb/kg  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  46.0/20.09

Maximum AC Output  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1400W

Surge AC Output  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1450W

AC Volts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 VAC

Rated AC Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11.6 A

Frequency  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  60 Hz

THD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.0%

Insulation Class  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Class B

Outlets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(2) 5-15R, (1) 12 VDC

DC Volts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 VDC

Rated DC Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 A

NOTE:

Power output and runtime are influenced by many factors, 

some of which are fuel quality, ambient temperature and engine 

condition. Output decreases approximately 3.5% for each 1,000 

feet above sea level and 1% for every 10 degrees above 60°F.

EMISSIONS INFORMATION

The Environmental Protection Agency (EPA) and California Air 

Resource Board (CARB) require that your generator comply with 

exhaust and evaporative emission standards. This generator is 

certified to meet the applicable EPA and CARB emission levels. 

Additional information regarding the requirements set by EPA and 

CARB is as follows:
It is important that you follow the maintenance specifications 

provided in this manual to ensure that your engine complies with 

the applicable emission standards for the duration of the engine’s 

life. This engine is certified to operate on gasoline. The emission 

control system on your generator consists of the following:
•  Fuel System 

•  Air Induction System

~  Fuel Tank 

  ~  Intake pipe/manifold

~  Fuel Cap 

  ~  Air cleaner

~ Carburetor 

• Ignition System

~  Fuel Lines 

  ~  Spark plug

•  Evaporative Control System    ~  Ignition module

~  Carbon Canister 

•  Exhaust System

~  Vapor Hoses 

  ~  Pulse Air Injection Valve

   

  ~ Muffler

The Emissions Compliance Period referred to on the Emissions 

Compliance Label indicates the number of operating hours for 

which the engine has been shown to meet Federal and California 

emission requirements. See the table below to determine the 

compliance period for your generator. The displacement of your 

generator is listed on the Emissions Compliance Label.

UNIT IDENTIFICATION 

(Figure 2)

1.  Carrying Handle: Lift the generator by this handle only.
2.  Spark Plug Cover: Allows access to the engine spark plug.
3.  Fuel System Primer: Used to prime the fuel system for 

starting.

4.  Fuel Cap Pressure Valve: Allows air to enter the fuel tank to 

equalize pressure.

5.  Fuel Tank Cap: Access to fuel tank for filling.
6.  Control Panel: location of generator controls and output 

receptacles.

7.  Air Intake Slats: Allows for cooling air to enter the housing.
8.  Muffler: Lowers engine exhaust noise (includes the spark 

arrestor).

9.  Choke: Cold engine starting aid
10. Left Side Service Cover: Allows access to air filter, fuel filter 

and oil fill.

11. Vent Hoses: Hoses allow venting of the carburetor.
12. Fuel Shutoff: Controls fuel supply to the carburetor.
13. Starter Rope: Pull rope for starting engine.

Figure 2 - Unit Identification

1

2

3

4

5

6

7

8

9

10

11

12

13

4

General Information

Содержание IX 1400

Страница 1: ...Inverter Generator Operator s Manual MODEL 005842 0 DEADLY EXHAUST FUMES ONLY use OUTSIDE far away from windows doors and vents NOT for use in critical life support applications SAVE this Manual Prov...

Страница 2: ...l Tank 8 Adding Engine Oil 8 To Add Engine Oil to the Crankcase 8 Maintenance 9 Generator Maintenance 9 Generator Maintenance Schedule 9 Cleaning the Generator 9 Engine Maintenance 10 Changing the Eng...

Страница 3: ...m carefully Their definitions are as follows Indicates a hazardous situation or action which if not avoided will result in death or serious injury Indicates a hazardous situation or action which if no...

Страница 4: ...cally conductive parts of the generator be properly connected to an approved earth ground Local electrical codes may also require proper grounding of the generator Consult with a local electrician for...

Страница 5: ...esource Council P O Box 309 Wilmington OH 45177 0309 5 ASAE EP 364 2 Installation and Maintenance of Farm Standby Electric Power available from www asabe org American Society of Agricultural Biologica...

Страница 6: ...trol system on your generator consists of the following Fuel System Air Induction System Fuel Tank Intake pipe manifold Fuel Cap Air cleaner Carburetor Ignition System Fuel Lines Spark plug Evaporativ...

Страница 7: ...rection non combustible surface with at least five 5 feet of clearance on all sides Never operate in an enclosed area or indoors NEVER use in the home in a vehicle or in partly enclosed areas such as...

Страница 8: ...rass etc as the cooling vents are located on the bottom of the unit Figure 5 Prime Fuel System FUEL SYSTEM VENT PLUNGER VENT Figure 6 Adjust Choke ENGINE CHOKE OPERATION ON I OFF O ADDING LOADS Once t...

Страница 9: ...not permit smoking open flame sparks or any other source of heat around a battery Wear protective goggles rubber apron and rubber gloves when working around a battery Battery electrolyte fluid is an e...

Страница 10: ...ays allow room for fuel expansion If tank is over filled fuel can overflow onto a hot engine and cause FIRE or an EXPLOSION Wipe up fuel spills immediately TO FILL THE FUEL TANK 1 Remove the fuel tank...

Страница 11: ...be retained in voids and crevices of the rotor and stator winding insulation Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these wind...

Страница 12: ...nge the engine oil after the first five 5 hours of operation Change the engine oil every 100 hours thereafter To change the engine oil Change the oil only when the fuel tank is low or nearly empty Tip...

Страница 13: ...an engine while in storage To avoid engine problems the use of a commercial fuel stabilizer prior to storage is recommended Follow the manufacturer s instructions when adding the fuel stabilizer If t...

Страница 14: ...e spark arrestor must be maintained in cood condition by the owner operator Clean and ispect the spark arrestor as follows Remove the screen retainer by removing the retainer clamp Slide the spark arr...

Страница 15: ...rk plug 4 Replace fuel filter 5 Replace FlexPower switch No AC output 1 Generator is overloaded OVERLOAD LED is on 2 AC voltage is low OVERLOAD LED is on 3 Inverter module is overheated OVERLOAD LED i...

Страница 16: ...14 Notes...

Страница 17: ...15 Notes...

Страница 18: ...coverage or responsibility if your equipment or a part component thereof has failed due to abuse neglect improper maintenance or unapproved modifications You are responsible for contacting a Generac A...

Страница 19: ...ntenance in the Owner s Manual shall be warranted for the period of time prior to first scheduled replacement point for that part If the part fails prior to the first scheduled replacement the part sh...

Страница 20: ...y any contaminated fuels oils or lack of proper oil levels Repairs or diagnostics performed by individuals other than Guardian Generac authorized dealers not authorized in writing by Generac Power Sys...

Страница 21: ...or Digital MODELO 005842 0 PELIGRO GASES DE ESCAPE MORTALES Util celo SOLAMENTE al AIRE LIBRE y lejos de ventanas puertas y respiraderos NO dise ado para uso en aplicaciones de soporte de vida cr tica...

Страница 22: ...agregar aceite al motor 8 Para a adir aceite de motor al c rter del motor 8 Mantenimiento 9 Mantenimiento del generador 9 Programa de mantenimiento del generador 9 Limpieza del generador 9 Mantenimie...

Страница 23: ...situaci n o acci n peligrosa que si no se evita puede ocasionar la muerte o una lesi n grave ADVERTENCIA Indica una situaci n o acci n peligrosa que si no se evita podr a ocasionar la muerte o una le...

Страница 24: ...El ctrico Nacional NEC requiere que el marco y las partes conductoras del exterior del generador est n conectadas correctamente a una tierra aprobada Los c digos el ctricos locales pueden tambi n requ...

Страница 25: ...on OH 45177 0309 5 ASAE EP 364 2 Instalaci n y mantenimiento de energ a el ctrica de respaldo en granjas disponible en www asabe org Sociedad Americana de Ingenieros Agr colas y Biol gicos2950 Niles R...

Страница 26: ...nsiste en lo siguiente Sistema de combustible Sistema de inducci n de aire Tanque de combustible Tuber a m ltiple de admisi n Tap n del combustible Limpiador de aire Carburador Sistema de ignici n L n...

Страница 27: ...en un veh culo o en el interior AUNQUE las puertas y ventanas est n abiertas selo S LO en exteriores y lejos de ventanas abiertas puertas ductos de ventilaci n y en reas que no acumular n el mortal ga...

Страница 28: ...los respiraderos de enfriamiento se localizan en la parte inferior de la unidad Figura 5 Cebado del sistema de combustible RESPIRADERO DE SISTEMA DE COMBUSTIBLE MBOLO RESPIRADERO Figura 6 Ajuste del a...

Страница 29: ...ositivo y el negro al negativo PELIGRO No permita fumar llamas abiertas chispas o ninguna otra fuente de calor alrededor de una bater a Use gafas protectoras delantal de hule y guantes de hule al trab...

Страница 30: ...LOSI N Limpie inmediatamente los derrames de combustible PARA LLENAR EL DEP SITO DE COMBUSTIBLE 1 Quite el tap n del dep sito de combustible 2 A ada el combustible lentamente dejando un espacio de dos...

Страница 31: ...devanado del rotor y del estator La acumulaci n de agua y suciedad en los devanados internos del generador disminuir eventualmente la resistencia del aislamiento de estos devanados PROGRAMA DE MANTEN...

Страница 32: ...inco 5 horas de operaci n Despu s cambie el aceite del motor cada 100 horas Para cambiar el aceite del motor CUIDADO Cambie el aceite solamente cuando el nivel de combustible en el dep sito est bajo o...

Страница 33: ...amiento Para evitar problemas del motor se recomienda el uso de un estabilizador comercialdecombustibleantesdelalmacenamiento Sigalasinstrucciones del fabricante al a adir el estabilizador de combusti...

Страница 34: ...chispas como sigue Retire el retenedor del filtro retirando la abrazadera del retenedor Deslice el filtro del supresor de chispas fuera del tubo de salida del silenciador Inspeccione el filtro y reem...

Страница 35: ...FlexPower No hay salida de CA 1 Generador sobrecargado la luz indicadora SOBRECARGA est encendida 2 Voltaje de CA bajo la luz indicadora SOBRECARGA est encendida 3 M dulo del inversor recalentado la l...

Страница 36: ...14 Notas...

Страница 37: ...15 Notas...

Страница 38: ...si su equipo o una parte o componente del mismo ha fallado debido al abuso mantenimiento inapropiado o modificaciones no autorizadas Usted es responsable de ponerse en contacto con un Centro de Garant...

Страница 39: ...e del mantenimiento necesario en el Manual del Usuario ser garantizada por el periodo de tiempo previo al primer remplazo programado para dicha pieza Si la pieza falla antes del primer reemplazo progr...

Страница 40: ...aminados o la falta de niveles apropiados Reparaciones o diagn sticos realizados por individuos diferentes a los concesionarios autorizados por Guardian Generac que no est n autorizados por escrito po...

Отзывы: