2

• When working on this equipment, remain alert at all times. 

Never work on the equipment when physically or mentally 

fatigued.

•  Never use the generator or any of its parts as a step. Stepping 

on the unit can stress and break parts, and may result in 

dangerous operating conditions from leaking exhaust gases, 

fuel leakage, oil leakage, etc.

EXHAUST & LOCATION HAZARDS

•  Never operate in an enclosed area or indoors! NEVER use 

in the home, in a vehicle, or in partly enclosed areas such 
as garages, even if doors and windows are open! ONLY use 
outdoors and far from open windows, doors, vents, and in an 
area that will not accumulate deadly exhaust.

• The engine exhaust fumes contain carbon monoxide, which 

you cannot see or smell. This poisonous gas, if breathed in 
sufficient concentrations, can cause unconsciousness or even 
death.

• Adequate, unobstructed flow of cooling and ventilating air 

is critical to correct generator operation. Do not alter the 
installation or permit even partial blockage of ventilation 
provisions, as this can seriously affect safe operation of the 
generator. The generator MUST be operated outdoors. 

•  This exhaust system must be properly maintained. Do nothing 

that might render the exhaust system unsafe or in noncompliance 

with any local codes and/or standards.

•  Always use a battery operated carbon monoxide alarm indoors, 

installed according to the manufacturers instructions.

•  If you start to feel sick, dizzy, or weak after the generator has 

been running, move to fresh air IMMEDIATELY. See a doctor, as 
you could have carbon monoxide poisoning.

ELECTRICAL HAZARDS

• The generator produces dangerously high voltage when in 

operation. Avoid contact with bare wires, terminals, connections, 
etc., while the unit is running, even on equipment connected 
to the generator. Ensure all appropriate covers, guards and 
barriers are in place before operating the generator. 

• Never handle any kind of electrical cord or device while 

standing in water, while barefoot or while hands or feet are wet. 

DANGEROUS ELECTRICAL SHOCK MAY RESULT.

•  The National Electric Code (NEC) requires the frame and external 

electrically conductive parts of the generator be properly 
connected to an approved earth ground. Local electrical codes 
may also require proper grounding of the generator. Consult 
with a local electrician for grounding requirements in the area.

• Use a ground fault circuit interrupter in any damp or highly 

conductive area (such as metal decking or steel work).

•  Do not use worn, bare, frayed or otherwise damaged electrical 

cord sets with the generator.

•  In case of accident caused by electric shock, immediately shut 

down the source of electrical power. If  this is not possible, 
attempt to free the victim from the live conductor. 

AVOID 

DIRECT CONTACT WITH THE VICTIM. 

Use a non-conducting 

implement, such as a rope or board, to free the victim from the 
live conductor. If the victim is unconscious, apply first aid and 
get immediate medical help.

FIRE HAZARDS

•  Gasoline is highly FLAMMABLE and its vapors are EXPLOSIVE. 

Do not permit smoking, open flames, sparks or heat in the 
vicinity while handling gasoline. 

•  Never add fuel while unit is running or hot.

 Allow engine to 

cool completely before adding fuel.

• Never fill fuel tank indoors. 

Comply with all laws regulating 

storage and handling of gasoline.

• Do not overfill the fuel tank. Always allow room for fuel 

expansion. 

If tank is over-filled, fuel can overflow onto a hot 

engine and cause FIRE or an EXPLOSION. Never store generator 
with fuel in tank where gasoline vapors might reach an open 
flame, spark or pilot light (as on a furnace, water heater or 
clothes dryer). FIRE or EXPLOSION may result. Allow unit to 
cool entirely before storage.

• Wipe up any fuel or oil spills immediately. Ensure that no 

combustible materials are left on or near the generator. Keep the 
area surrounding the generator clean and free from debris and 
keep a clearance of five (5) feet on all side to allow for proper 
ventilation of the generator.

•  Do not insert objects through unit’s cooling slots.

 

 Save These Instructions – The manufacturer suggests that these rules for safe operation be copied 

and posted near the unit's installation site. Safety should be stressed to all operators and potential 

operators of this equipment. If you loan this unit to anyone, be sure to also loan this Owner's Manual 

and advise that it be read thoroughly before operating the unit.

Safety Rules

Содержание IX 1400

Страница 1: ...Inverter Generator Operator s Manual MODEL 005842 0 DEADLY EXHAUST FUMES ONLY use OUTSIDE far away from windows doors and vents NOT for use in critical life support applications SAVE this Manual Prov...

Страница 2: ...l Tank 8 Adding Engine Oil 8 To Add Engine Oil to the Crankcase 8 Maintenance 9 Generator Maintenance 9 Generator Maintenance Schedule 9 Cleaning the Generator 9 Engine Maintenance 10 Changing the Eng...

Страница 3: ...m carefully Their definitions are as follows Indicates a hazardous situation or action which if not avoided will result in death or serious injury Indicates a hazardous situation or action which if no...

Страница 4: ...cally conductive parts of the generator be properly connected to an approved earth ground Local electrical codes may also require proper grounding of the generator Consult with a local electrician for...

Страница 5: ...esource Council P O Box 309 Wilmington OH 45177 0309 5 ASAE EP 364 2 Installation and Maintenance of Farm Standby Electric Power available from www asabe org American Society of Agricultural Biologica...

Страница 6: ...trol system on your generator consists of the following Fuel System Air Induction System Fuel Tank Intake pipe manifold Fuel Cap Air cleaner Carburetor Ignition System Fuel Lines Spark plug Evaporativ...

Страница 7: ...rection non combustible surface with at least five 5 feet of clearance on all sides Never operate in an enclosed area or indoors NEVER use in the home in a vehicle or in partly enclosed areas such as...

Страница 8: ...rass etc as the cooling vents are located on the bottom of the unit Figure 5 Prime Fuel System FUEL SYSTEM VENT PLUNGER VENT Figure 6 Adjust Choke ENGINE CHOKE OPERATION ON I OFF O ADDING LOADS Once t...

Страница 9: ...not permit smoking open flame sparks or any other source of heat around a battery Wear protective goggles rubber apron and rubber gloves when working around a battery Battery electrolyte fluid is an e...

Страница 10: ...ays allow room for fuel expansion If tank is over filled fuel can overflow onto a hot engine and cause FIRE or an EXPLOSION Wipe up fuel spills immediately TO FILL THE FUEL TANK 1 Remove the fuel tank...

Страница 11: ...be retained in voids and crevices of the rotor and stator winding insulation Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these wind...

Страница 12: ...nge the engine oil after the first five 5 hours of operation Change the engine oil every 100 hours thereafter To change the engine oil Change the oil only when the fuel tank is low or nearly empty Tip...

Страница 13: ...an engine while in storage To avoid engine problems the use of a commercial fuel stabilizer prior to storage is recommended Follow the manufacturer s instructions when adding the fuel stabilizer If t...

Страница 14: ...e spark arrestor must be maintained in cood condition by the owner operator Clean and ispect the spark arrestor as follows Remove the screen retainer by removing the retainer clamp Slide the spark arr...

Страница 15: ...rk plug 4 Replace fuel filter 5 Replace FlexPower switch No AC output 1 Generator is overloaded OVERLOAD LED is on 2 AC voltage is low OVERLOAD LED is on 3 Inverter module is overheated OVERLOAD LED i...

Страница 16: ...14 Notes...

Страница 17: ...15 Notes...

Страница 18: ...coverage or responsibility if your equipment or a part component thereof has failed due to abuse neglect improper maintenance or unapproved modifications You are responsible for contacting a Generac A...

Страница 19: ...ntenance in the Owner s Manual shall be warranted for the period of time prior to first scheduled replacement point for that part If the part fails prior to the first scheduled replacement the part sh...

Страница 20: ...y any contaminated fuels oils or lack of proper oil levels Repairs or diagnostics performed by individuals other than Guardian Generac authorized dealers not authorized in writing by Generac Power Sys...

Страница 21: ...or Digital MODELO 005842 0 PELIGRO GASES DE ESCAPE MORTALES Util celo SOLAMENTE al AIRE LIBRE y lejos de ventanas puertas y respiraderos NO dise ado para uso en aplicaciones de soporte de vida cr tica...

Страница 22: ...agregar aceite al motor 8 Para a adir aceite de motor al c rter del motor 8 Mantenimiento 9 Mantenimiento del generador 9 Programa de mantenimiento del generador 9 Limpieza del generador 9 Mantenimie...

Страница 23: ...situaci n o acci n peligrosa que si no se evita puede ocasionar la muerte o una lesi n grave ADVERTENCIA Indica una situaci n o acci n peligrosa que si no se evita podr a ocasionar la muerte o una le...

Страница 24: ...El ctrico Nacional NEC requiere que el marco y las partes conductoras del exterior del generador est n conectadas correctamente a una tierra aprobada Los c digos el ctricos locales pueden tambi n requ...

Страница 25: ...on OH 45177 0309 5 ASAE EP 364 2 Instalaci n y mantenimiento de energ a el ctrica de respaldo en granjas disponible en www asabe org Sociedad Americana de Ingenieros Agr colas y Biol gicos2950 Niles R...

Страница 26: ...nsiste en lo siguiente Sistema de combustible Sistema de inducci n de aire Tanque de combustible Tuber a m ltiple de admisi n Tap n del combustible Limpiador de aire Carburador Sistema de ignici n L n...

Страница 27: ...en un veh culo o en el interior AUNQUE las puertas y ventanas est n abiertas selo S LO en exteriores y lejos de ventanas abiertas puertas ductos de ventilaci n y en reas que no acumular n el mortal ga...

Страница 28: ...los respiraderos de enfriamiento se localizan en la parte inferior de la unidad Figura 5 Cebado del sistema de combustible RESPIRADERO DE SISTEMA DE COMBUSTIBLE MBOLO RESPIRADERO Figura 6 Ajuste del a...

Страница 29: ...ositivo y el negro al negativo PELIGRO No permita fumar llamas abiertas chispas o ninguna otra fuente de calor alrededor de una bater a Use gafas protectoras delantal de hule y guantes de hule al trab...

Страница 30: ...LOSI N Limpie inmediatamente los derrames de combustible PARA LLENAR EL DEP SITO DE COMBUSTIBLE 1 Quite el tap n del dep sito de combustible 2 A ada el combustible lentamente dejando un espacio de dos...

Страница 31: ...devanado del rotor y del estator La acumulaci n de agua y suciedad en los devanados internos del generador disminuir eventualmente la resistencia del aislamiento de estos devanados PROGRAMA DE MANTEN...

Страница 32: ...inco 5 horas de operaci n Despu s cambie el aceite del motor cada 100 horas Para cambiar el aceite del motor CUIDADO Cambie el aceite solamente cuando el nivel de combustible en el dep sito est bajo o...

Страница 33: ...amiento Para evitar problemas del motor se recomienda el uso de un estabilizador comercialdecombustibleantesdelalmacenamiento Sigalasinstrucciones del fabricante al a adir el estabilizador de combusti...

Страница 34: ...chispas como sigue Retire el retenedor del filtro retirando la abrazadera del retenedor Deslice el filtro del supresor de chispas fuera del tubo de salida del silenciador Inspeccione el filtro y reem...

Страница 35: ...FlexPower No hay salida de CA 1 Generador sobrecargado la luz indicadora SOBRECARGA est encendida 2 Voltaje de CA bajo la luz indicadora SOBRECARGA est encendida 3 M dulo del inversor recalentado la l...

Страница 36: ...14 Notas...

Страница 37: ...15 Notas...

Страница 38: ...si su equipo o una parte o componente del mismo ha fallado debido al abuso mantenimiento inapropiado o modificaciones no autorizadas Usted es responsable de ponerse en contacto con un Centro de Garant...

Страница 39: ...e del mantenimiento necesario en el Manual del Usuario ser garantizada por el periodo de tiempo previo al primer remplazo programado para dicha pieza Si la pieza falla antes del primer reemplazo progr...

Страница 40: ...aminados o la falta de niveles apropiados Reparaciones o diagn sticos realizados por individuos diferentes a los concesionarios autorizados por Guardian Generac que no est n autorizados por escrito po...

Отзывы: