GEM-P801

Installation Instructions

Control Panel/Communicator

WI1089 09/01

© NAPCO 2000

®

Содержание GEM-P801

Страница 1: ...GEM P801 Installation Instructions Control Panel Communicator WI1089 09 01 NAPCO 2000 ...

Страница 2: ...ireless Ready Bell Supervision Line Cut Detection Answering Machine Override Second Call 50 Event Log Communicator 2 Telephone Numbers Backup Reporting Pager Format Point ID Format Individually Report 8 Users Opening after Alarm Report Cancel Code Conditional Closing Report For Technical Assistance Contact the NAPCO Toll Free Helpline 800 645 9440 NAPCO Security Systems Inc 333 Bayview Avenue Amit...

Страница 3: ... Rechargeable 12 VDC 7 AH BATTERY minimal requirement Transformer and Battery Required Transformer NAPCO TRF12 OR BASLER 16 5 VAC 20VA Required Battery 12V 4 AH or 7 AH Rechargeable Change Battery every 5 years or as required Maximum Charging Current 165 mA Maximum Input Current 2 58 A Loop Characteristics Loop Voltage 5 Volts Loop Current 1 1mA Loop Resistance 300Ω per zone max Device Specificati...

Страница 4: ...Sentrol 449AT 449C 449CRT 449CST 449CSRT 449CSRH 449CSST 449CLT 449CSLT 449CTE 741U 742U 712U 722U 732U 711U 721U 721UT 731U 701U 702U 702RE 702RU System Sensor 1112 2112 2112T 2112TSRB 2100 2100T 1100 NAPCO FW 4 FW 2 Optional Accessories GEM RECV XP8 Wireless Receiver GEM TRANS2 Window Door Transmitter GEM KEYF Keyfob Transmitter GEM WP Wireless Waterproof Panic Button GEM SMK Wireless Smoke Dete...

Страница 5: ...be automatically downloaded uploaded using the PCPreset utilty For Site Initiated Downloaded see Auto Download ID Number 93 Local Downloading Wire as shown in Figure 1 Use the power up or A6 method of establishing a connection The power up method is recommended if the panel is attempting to report Remote Downloading Wire as shown in Figure 2 The panel can be remotely download uploaded using any on...

Страница 6: ...eat detectors rather than smoke detectors are recommended in kitchens attics and garages due to conditions that may result in false alarms and improper operation Refer to NFPA Standard 74 National Fire Protection Association Batterymarch Park Quincy MA 02269 for additional information including proper mounting methods Wiring Grounding the Panel Connect the control panel EARTH GROUND screw through ...

Страница 7: ... programming option s that have been selected in programming blocks 08 23 25 26 2 Connect the device controlled by the PGM between PWR and the PGM terminal maximum load of 50 mA Keypad Operation Keypad zone LEDs indicate zone status ARMED STATUS and HSYSTEM LEDs provide system status The keypad sounder provides feedback beeps for correct and incorrect entries Keypad Sounder 3 QUICK BEEPS Panel Arm...

Страница 8: ...for Interior 81 84 Zones programmed as Home Away with Delay Zones can be armed regardless of the state of the Exit Entry Zones when the M or N keys on the Keyfob have been programmed for Full Set 81 84 To arm the system with all zones protected press the K key Press and hold the M or N key for 1 5s to fully set the system The LED on the Keyfob indicate the Keyfob has transmitted the signal Program...

Страница 9: ...Keyfob GEM KF All zones in the system can be armed regardless of the state of the Exit Entry Zone when arming with a Keyfob and using an AUX key programmed as Full Set Press ON and press and hold the A1 or A2 keys for 1 5s when leaving the premises All zones including Home Away Zones are armed Bypassing a zone Press the B key then the zone number to be bypassed While the panel is DISARMED the bypa...

Страница 10: ...battery indication will be displayed A battery test is also performed on power up after a 3 minute delay A battery test occurs every 4 hours when Household Fire 96 3 has been selected D Easy Arm Press this key to arm the panel To disarm the panel a valid Arm Disarm code must be entered Requires Easy Exit Easy Arm 21 2 to be enabled E Interior Enter this command to bypass all Exit Entry Follower Zo...

Страница 11: ...l Figure 5 indication of each transmitter s signal strength The signal strength metering is based on a scale of 4 to 10 with 4 being marginal and 10 being excellent The keypad will beep out a number from 1 4 corresponding to the signal strength of the transmitter See Table 6 Each beep is 1 second long The keypad will sound a short beep for transmitters with signal strengths of 3 or less Signal Str...

Страница 12: ...r up delay and do not display or cause an alarm if faulted when the system powers up Pressing the C key cancels the 3 minute timer Group Bypassing Zones programmed as Exit Entry Follower Zones will be Group bypassed if the E key is pressed while disarmed or within the Exit Delay Auto Interior Bypassing Also program zones as Home Away with Delay Zone s 01 to automatically bypass at the expiration o...

Страница 13: ...Entry Delay Time 11 may be programmed for up to 255 seconds 4 minutes a value of 0 defaults to 30 seconds Entry Delay may be canceled by pressing F before or after arming 12 Burg Steady Output Time out Can be programmed from 1 to 255 min 4 hours 0 means output will stay ON until turned off by entering an Arm Disarm Code 13 Fire Pulsed Temporal Output T O Can be programmed from 1 to 255 min 4 hours...

Страница 14: ...ithin 3 three feet from the Control Panel 21 Keypad Features 2 1 Audible Panic Keypad Panic will not turn the Bell on unless this option is programmed 2 Exit Entry with Urgency select to give an audible indication of Exit and Entry times During the last 10 seconds of entry and exit time the keypad sounds a distinct sound to indicate the premises must be left or the panel must be disarmed 3 Display...

Страница 15: ...ail to Communicate Display This option prevents the keypad from either indicating or sounding when a Fail to Communicate has occurred 4 Inhibit Low Battery Display Program to inhibit the Low Battery Display at the keypad Low Battery Reporting is not inhibited The programming option is not permitted for UL installations 27 Keyswitch Polarity 1 Keyswitch Polarity program to convert keyswitch operati...

Страница 16: ... Report Program to activate a Low Battery report 3 Trouble Report Program to activate a Trouble report 4 Fire Report Program to activate a Fire report Includes Bell Cut Fire Trouble Receiver Fail to Respond Receiver Tamper Receiver JAM Wireless Smoke Low Battery Wireless Smoke Supervisory Fail Point ID format will report trouble s by device and ID number 38 System Restore Report Telco 1 1 AC Resto...

Страница 17: ...or 42 and or 52 7 is selected pager data will be displayed as shown in Figure 8 If Pager Format is selected 4 2 format must be programmed and Sumcheck is not permitted If a PIN number is required refer to Leading Digits 47 Pager Alarm data is the same as 4 2 format with the exception that the 2 digit Report Code is transmitted before the 4 digit Subscriber ID 47 Leading Digits Pager PIN Number If ...

Страница 18: ...nditional closing by User 2 with zones 2 and 3 bypassed would be as follows 1234 C2 F2 F3 63 System Report Codes Program a 2 digit report code for Keypad Fire Keypad AUX Keypad Panic Test Timer AC Fail Low Battery Trouble and Fire 64 System Restore Code The code sent when a system condition restores The second digit of the 2 digit restore code is the second digit of the System Report Code 63 For e...

Страница 19: ... 71 78 Wireless Transmitters Enter the RF ID and the point number that is to be mapped to the zone Programming Example Map point 1 of a window door transmitter with an RF ID of 0012B0 0 to Zone 3 1 Enter Dealer Mode 2 Enter C beeps 73 beeps 3 Enter 12G200 Enter 1 beeps Note If the RF ID in step 3 is not entered correctly the keypad will emit a 1 second tone indicating incorrect entry Repeat steps ...

Страница 20: ...e time programmed in Wireless Smoke Supervisory Timer a system trouble RF Smoke Supervisory Failure will be indicated on the keypad Program Wireless Smoke Supervisory Timer 17 to change the time from the default time of 8 hours Refer to Household Fire 96 3 Note Mark Smoke Detectors Smoke 1 through Smoke 4 in order to identify them in the event of a supervisory or battery failure If Household Fire ...

Страница 21: ...User code is a program code as well as an Arm Disarm code The default User Code is 1234 If User 1 Code Lockout is programmed the User 1 Code cannot be programmed from User Program Mode 96 Dealer Options 1 1 Dealer Code Lockout Program to prevent the Dealer Code from changing with a panel default 2 User 1 Code Lockout If programmed the User 1 Code cannot be programmed from User Program Mode 3 House...

Страница 22: ...structions Note All programming within Programming Blocks 96 97 will not change if the panel is defaulted 98 Number of Re Dials The Number of re dial attempts made by the panel before indicating a Fail to Communicate System Trouble 1 3 ...

Страница 23: ...the reset button is pressed or the trouble has been acknowledged by pressing the C key System Trouble Reporting The following system troubles when enabled to report to Telco 1 37 3 or Telco 3 57 3 will send the report code programmed in Trouble Report 63 if reporting using a pulse format System Trouble Pulse Report Code Bell Cut F1 2 Wire Fire Trouble F1 Rcvr Fail to Respond F1 Receiver Tamper F1 ...

Страница 24: ...e transmitted 4 Receiver Jam A signal is blocking the normal reception of transmissions from the wireless devices Ensure that the green LED on the receiver is not on continuously refer to receiver manual WI850 3 Beeps 1 6 Wireless Transmitter Low Battery The battery in the wireless transmitter is low and should be replaced This transmitter is on the zone corresponding to the number of the zone lig...

Страница 25: ...ime mode Press A5 4 When using a piezo on the Bell Output it constantly buzzes This is due to the fact that there is a constant loop current flowing through the Bell circuit for supervision To eliminate this cut resistor R26 which is located directly above Terminal 9 just below the heat sink 5 Where are the fuses The control panel incorporates advanced circuitry which automatically limits the curr...

Страница 26: ...int 1 and point 2 is jumped out If using internal reed make sure J1 is cut and both Point 1 and Point 2 terminals are jumped out 10 Keypad LEDs Flicker The Keypad is not receiving a POLL from the Panel Check Keypad wiring 1 The Panel is in the process of being Uploaded Downloaded 2 The panel is powering up LED s will flicker until panel has reset and is polling the keypad 3 The connection from the...

Страница 27: ... FIVE YEARS COLD WATER GROUND CONNECTION USE ONLY COLD WATER PIPE OR BURIED GROUND ROD USE AT LEAST 16 AWG WIRE 1 COMBINED STANDBY KEYPAD CURRENT AUX POWER CURRENT FIRE POWER PGM CURRENT 2 RESIDENTIAL FIRE REQUIRES A 7AH BATTERY 3 UNIT INTENDED TO BE MOUNTED VERTICALLY ON WALL 4 REFER TO WI1089 FOR COMPATIBLE TWO WIRE SMOKE DETECTORS DO NOT MIX DIFFERENT MODELS 5 THIS PANEL SHALL BE CHECKED BY A Q...

Страница 28: ...ot limited to any or all of the following criminal tampering electrical or communications disruption it is possible for the system to fail to perform as expected NAPCO does not represent that the product system may not be compromised or circumvented or that the product or system will prevent any personal injury or property loss by burglary robbery fire or otherwise nor that the product or system w...