GEMAŞ Genel Mühendislik Mekanik San.veTic.A.Ş.
İTOB Organize Sanayi Bölgesi 10001 Sok.No:28 Menderes/İZMİR TURKEY
Tel:0232 799 0 333 Fax:0232 799 0 330 www.gemas.com.tr [email protected]
10
EN
GEMAŞ PURITRON GSC Installation and User Manual
V4.1
4.It is the symbol of pool cover.
It is available in the devices with the pool cover closing
control.
Thanks to the pool cover closing control on the device; It provides the ability to adjust the
chlorine production rate when the cover is closed. A switch with N.O contact (Dry Contact) is
connected to the pool cover closing control connection socket. When the pool cover is closed, the
signal coming from the switch turns the device to the cover mode and the icon appears on the screen. When
the device is operating in the covered mode, the desired production value is increased and decreased with the
direction buttons.
3.2.Setting Menu
The setting menu is an interface where the settings pages and
parameters of the device are located. Allows the device to work
at an optimum level with the changes and adjustments made.
The device is turned OFF to enter the setting menu. An image will
appear on the LCD screen as shown. While the device is in the
OFF position, press the
MENU
button for 3 seconds. The device
will automatically switch to the setting menu.
The contents of the setting menu are shown in the adjacent
table. The table indicates the setting pages and parameters
within the pages.
3.2.1. POLARITY PERIOD
Although the physical properties of the water used vary according to geographical regions, it inevitably
contains certain proportions of calcium, magnesium, iron and other minerals. When the water is cold, these
suspended minerals separate from the water during electrolysis, some of which adhere to the electrodes in the
reservoir. After a certain time, the electrodes are completely covered with a substance called lime. Since the
lime layer is insulating, it makes the electrical flow between electrodes difficult. As a result, chlorine production
efficiency drops. This lime formed on the electrodes should be cleaned periodically.
This cleaning process device; It has the feature of automatically
changing the polarization. Polarity period page is the page where the
polarization change time is set. The page is entered by pressing the
OK
button once, and the
MENU
button must be pressed once to exit
the page. When entering the setting page, the parameter value is
changed with the
UP
and
DOWN
direction buttons. When the desired
value is given, it is selected and saved with the
OK
button.
3.2.2. LANGUAGE
This is the page where the operating language setting of the device
is made. The languages defined on the device are ENGLISH -
TURKISH - FRENCH - BULGARIAN - GERMAN - HUNGARY - SPANISH.
The page is entered by pressing the OK button once, and the MENU
button must be pressed once to exit the page. The working language
is changed with UP and DOWN direction buttons. When the desired
working language is displayed, press the OK button once, the working
language is selected and saved.
3.2.3.P.COVER PROC.
Thanks to the pool cover closing control on the device; It provides
the ability to adjust the chlorine production rate when the cover is
closed.
A switch with N.O contact (Dry Contact) is connected to the pool
cover closing control connection socket. When the pool cover is
closed, the signal coming from the switch turns the device to the
cover mode and the icon appears on the screen. When the device is
operating in the covered mode, the desired production value is
increased and decreased by the direction buttons.
3.2.4.PROGRAM MENU
It is the setting page where GEMAŞ technical personnel can intervene. Making changes to this page may
harm the general operation of the device.
Settings
1 - POLARITY PERIOD
POLARMA CLOCK
2 - LANGUAGE
ENGLISH
TURKISH
FRENCH
BULGARIAN
GERMAN
HUNGARIAN
SPANISH
3 - P.COVER PROC.
P.COVER CL
4 - PROGRAM MENU
PASSWORD