4.2.Advices
The bipolar cells of the GSC salt water chlorinator, have been produced using a special technique, with an
extraordinary duration and resistance under high-quality standards. However, some factors prevent you from
getting the full and longest performance from the electrode. These:
•
Operating with a limescale on the surface of the electrode.
•
Operating the device in a system with excessive chlorine concentration. (Chlorine over 3.00 ppm is
corrosive.)
•
Operating the device in a system with a high or low pH.
•
Operating the device in a salt-free system or a system with a high salt concentration.
•
Operating the device in water below 10 ° C.
•
Adding salt while the appliance is running.
•
Injecting pH regulator without skimmer or bottom strainer in place.
It is recommended to periodically check the cell terminals and lubricate them against sulfurization. Situations
where you need to turn off the equipment:
•
If there is not enough water in the cell.
•
While the filter is being cleaned.
•
While the pool is being drained.
•
When the water is frozen.
•
While the cell is being cleaned.
4.3.Fault Codes and Recommended Solutions
Fault Code
Possible Fault
Solution Way
ERR1
Cable is broken or not making
contact.
Check cable and connection
terminals, replace if necessary.
There is a problem with the
electrode cable connection.
Check the electrode cable
connection terminals.
Dense lime
Remove scale from the cell and
lower the polarity period.
ERR2
There is lime
Remove scale from the cell and
lower the polarity period.
The water is too hard
Soften the water.
ERR3
There is a short circuit at the
device output.
Check the device electrode cable,
electrode connection terminals
and replace if necessary.
ERR4
Electronic card failure
Contact the manufacturer.
LOW SALT
There is not enough salt in the
pool water.
Add salt to the pool water.
Device Does Not Work - No
Display Screen
220VAC-50Hz energy is not
supplied to the device.
Check the energy of the power
cable ends connected to the
panel.
Check the power cable.
Check the fuse in the glass fuse
holder.
Make sure that the device On /
Off switch is in the on position.
The device is in Stand-By mode
Press the MENU Button once.