2.1.Control Unit Installation
1.Power Cord Input Socket
2.Glass Fuse Holder
3.Device On / Off Switch
4.Electrode Cable Output Coupling
5.Pool Cover Closing Control Connection Socket (Dry Switch)
For the mounting of the control unit, a place that provides easy access and reading should be determined.
The control unit must be in a place where there is airflow, protected from rain and there is no danger of
water leakage.
If there are acid tanks in the area where the control unit is located, there must be airflow in the
environment. Otherwise, electronic components may corrode due to the acid effect.
The control unit should be considered to be within 1.5m of the electrode cell.
For the assembly process; Mark the hole locations on the wall you will mount on the hanging bracket.
Drill holes in the marked places, fix the hanging bracket with the help of dowels and screws and place the
control unit on the bracket.
Connect the ground wire (yellow and green) of the 220V AC power unit cable to the grounding line of the
installation. Connect the phase (brown) and neutral (blue) wires to the outputs of the pump contactor.
Salt chlorine generator should be used in parallel with the pump and while circulating in
the water electrode cell. The device should never be operated without water flow in the
cell.