GEMAŞ PURITRON GSC Installation and User Manual   

 

 

   

   V4.1 

  3.3. Use of the device 

 

3.3.1. Switching the Device to On (ON) - Off (OFF) Mode

 

 

When the GSC Salt Water Chlorinator is powered and started, the switch at the bottom of the device (2.1. 

Control Unit Installation, Item 3) must be turned on. The device will be in On (ON) or Off (OFF) mode according 

to the last mode it was in. The mode in which the device is can be understood from the status of the LCD 

display. The production screen is displayed when the device is in the ON mode, and the “PURITRON” is 

displayed in the OFF mode. 

 

 

3.3.2. Switching the Device to Chlorine Production 

 

The device is turned on with the on / off button (3.1. Control Panel Item 2). Instantaneous CL production 

percentage, polarity direction icon will appear on the screen of the device. In the meantime, the CL production 
percentage can be increased or decreased by pressing the direction buttons. Also, if the OK button is pressed 

once, the current drawn by the electrodes is shown and then it will disappear automatically. 

 

3.3.3. Switching the Device to Boost Mode 

 

The chlorine need of the pool is provided quickly,thanks to the Boost Mode on the device. Device runs at full 

capacity for 8 hours and then returns to the production capacity set in the normal operation with the Boost 

Mode. When the device is in ON mode, the device is switched to Boost mode by holding down the OK button for 

3 seconds.When the device is in boost mode, “BOOST” appears where CL production rate is shown. 

 

While the device is working in Boost mode ; changing the production capacity with the 
directional buttons takes the device out of Boost mode. 

 

3.3.4. Operating the Device with the Pool Cover 

 

Thanks to the pool cover closing control on the device; it allows adjustment of chlorine production rate when 

the cover is closed. A dry contact switch is connected to the pool cover closing control connection socket. When 

the pool cover is closed,the signal from switch brings the device to the cover mode and its symbol appears on 

display.When the device operates in the “covered” mode, the desired production value is increased and 

decreased by the direction buttons. 

 

4.CLEANING - MAINTENANCE INSTRUCTIONS 

  4.1. Electrode Cleaning 

Although the physical properties of the water used vary according to geographical regions, it inevitably 

contains certain proportions of calcium, magnesium, iron and other minerals. While the water is cold, these 

suspended minerals separate from the water during electrolysis, some of which adhere to the electrodes in the 

reservoir. After a certain time, the electrodes are completely covered with a substance called lime. Since the 

lime layer is insulating, they make the electrical flow between electrodes difficult. As a result, chlorine 
production efficiency drops. This lime formed on the electrodes should be cleaned periodically.

 

This cleaning process device; It has the feature of automatically changing the polarization. However, in cases 

where the calcium concentration is too high, this feature may not completely remove the limescale. The lime 

residue in the cell should be checked regularly and the cell should be cleaned manually when necessary.

 

1.

Turn off the pump and salt chlorine generator. 

2.

Close the water inlet and water outlet valves of the electrode cell. 

3.

Open the threaded electrode head, remove the electrode cable from the terminal properly and take the 

electrode out of the chamber. 

4.

Ideally, if the electrode is allowed to dry for a day, the limescale will release itself. Take care and pay 

attention not to damage the sensitive cap of the electrode during the procedure. During this process, never hit 
the electrode with metal material that could scratch it. Pressurized water can be used to dissolve limescale. 

5.

If the pressurized water could not remove the scale residue, you can immerse the electrode in a 20% 

hydrochloric acid solution. The terminals on the upper part of the electrode should not come into contact with 
the solution. 

6.

Immediately after cleaning, the electrode should be rinsed with clean water, the location of the terminals 

should be carefully dried and reassembled. 

 

Never keep the electrode in acid for more than 5 minutes! Do not scratch the electrode with 

metal objects! For safety reasons, dilute the acid with water! 

Содержание 064250

Страница 1: ... veTic A Ş İTOB Organize Sanayi Bölgesi 10001 Sok No 28 Menderes İZMİR TURKEY Tel 0232 799 0 333 Fax 0232 799 0 330 www gemas com tr info gemas com tr 1 GSC 10 20 30 064250 064260 064270 INSTALLATION USER MANUAL KURULUM KULLANIM KILAVUZU ...

Страница 2: ...ay pose a danger to the device the place used and the people using it The ground connection must be connected to a proper grounding line Electrical energy should be taken from a line with residual current protection ATTENTION Serious injury or even death can occur as a result of electric shock So seek help from experienced technicians In terms of life safety and product It should be installed in p...

Страница 3: ... arise from mixing chlorine and acids that produce heavy gases are eliminated with this system Short storage period of purchased hypo solutions in summer conditions concentration loss due to heat significantly increases the attractiveness of the system In addition to these an extremely glowing and clear water quality can be achieved with the high oxidation effect of oxygen radicals produced in add...

Страница 4: ... device the instant chlorine need of the pool is provided The pool cover has a closing control input Thanks to the LCD screen it provides the opportunity to monitor the current during operation The device records the total working time It can be easily applied to the existing pool The recommended minimum salinity is 4000ppm 4kg m3 The device can be used in seawater which is 35000ppm 1 1 Technical ...

Страница 5: ...ct the safety of life and property in the Salt Chlorine Generator For electrical measures to fulfill their function warnings regarding residual current relay and grounding must be taken into account Leakage relay Use a CE certified residual current relay that you are sure it works Make sure that the relay you will use controls the Salt Chlorine Generator Strictly test the Residual Current Relay ev...

Страница 6: ...ere are acid tanks in the area where the control unit is located there must be airflow in the environment Otherwise electronic components may corrode due to the acid effect The control unit should be considered to be within 1 5m of the electrode cell For the assembly process Mark the hole locations on the wall you will mount on the hanging bracket Drill holes in the marked places fix the hanging b...

Страница 7: ...taching the electrode Electrode it must be seated in the chamber in the right direction The open part of the electrode should be towards the water inlet pipe connection Make sure that the silicone gasket is in place and seated in a leak proof way Connect the electrode cable through the choke gasket and the screwed electrode head to the cable connection terminals Close the threaded electrode head I...

Страница 8: ...ll decrease The water of the pool should meet the following values Salt 5 6 Kg m pH Concrete Pool 7 2 7 6 Polyester 6 8 7 0 TAC 60 100 ppm TH 15 20 French Stabilizer 20 30 ppm or manufacturer s recommendation Temperature 10 C 2 4 Adding Salt During the salt addition process the system should be completely shut down until all of the salt is dissolved If the system is operated before the salt is com...

Страница 9: ...F turning on and off entering the setting menu holding the device off holding down for 3 seconds while it is OFF and leaving the pages and parameters in the setting menu 3 It performs the functions of making selections in pages and parameters in the setting menu confirming and saving the adjusted parameters By holding it down for 3 sec during the operation the device switches to boost mode and run...

Страница 10: ...covered with a substance called lime Since the lime layer is insulating it makes the electrical flow between electrodes difficult As a result chlorine production efficiency drops This lime formed on the electrodes should be cleaned periodically This cleaning process device It has the feature of automatically changing the polarization Polarity period page is the page where the polarization change t...

Страница 11: ... from switch brings the device to the cover mode and its symbol appears on display When the device operates in the covered mode the desired production value is increased and decreased by the direction buttons 4 CLEANING MAINTENANCE INSTRUCTIONS 4 1 Electrode Cleaning Although the physical properties of the water used vary according to geographical regions it inevitably contains certain proportions...

Страница 12: ...n Situations where you need to turn off the equipment If there is not enough water in the cell While the filter is being cleaned While the pool is being drained When the water is frozen While the cell is being cleaned 4 3 Fault Codes and Recommended Solutions Fault Code Possible Fault Solution Way ERR1 Cable is broken or not making contact Check cable and connection terminals replace if necessary ...

Страница 13: ... contrary to the instructions for use b Malfunctions arising from incorrect electrical connections c Malfunctions arising from crash fall breakage and similar accidents d Faults are caused by liquid contact in the control unit e Malfunctions arising from the operation without the bypass circuit by the connection diagram Malfunctions arising from the liquid contact in the control unit f Malfunction...

Страница 14: ...ekse kullanılan mahal ve kullanan kişiler için tehlike arz edebilir Topraklama bağlantısını düzgün bir topraklama hattına bağlayarak gerçekleştiriniz Elektrik enerjisi kaçak akım koruması bulunan bir hattan alınız DİKKAT Elektrik çarpması sonucu ciddi yaralanmalar hatta ölümler meydana gelebilir Bu yüzden tecrübeli teknisyenlerden yardım isteyiniz Can güvenliği ve ürün açısından Montajı çocukların...

Страница 15: ...cak makina dairelerinde ağır gaz çıkartan klor ve asitlerin birbirine karıştırılmasından doğabilecek ölümcül kaza riskleri bu sistemle ortadan kalkmaktadır Satın alınan hipo çözeltilerinin yaz koşullarında depolama süresinin kısalığı sıcaktan kaynaklı konsantrasyon kaybı sistemin cazibesini önemli ölçüde arttırmaktadır Bunlara ek olarak proseste klorun yanı sıra üretilen oksijen radikallerinin yük...

Страница 16: ...ost çalışma modu sayesinde havuzun ani klor ihtiyacı karşılanır Havuz örtüsü kapanma kontrol girişine sahiptir LCD ekran sayesinde çalışma anındaki akımı görüntüleme imkanı sağlar Cihaz toplam çalışma süresini kaydeder Mevcut havuza kolaylıkla uygulanabilir Önerilen minimum tuzluluk 4000ppm dir 4kg m3 Cihaz 35000ppm olan deniz suyunda da kullanılabilir özelliğe sahiptir 1 1 Teknik Özellikler GSC10...

Страница 17: ...ik önlemler alınmıştır Elektriksel önlemlerin işlevini yerine getirebilmesi için mutlaka kaçak akım rölesi ve topraklama ile ilgili uyarıların dikkate alınması gerekmektedir Kaçak Akım Rölesi CE belgeli ve çalıştığından emin olduğunuz bir kaçak akım rölesi kullanın Kullanacağınız rölenin Tuz Klor Jeneratörünü kontrol ettiğinden emin olun Kesinlikle her yıl Kaçak Akım Rölesini test edin Kaçak Akım ...

Страница 18: ... olmalıdır Kontrol ünitesi bulunduğu bölgede asit tankları var ise ortamda hava akışı olması gerekmektedir Aksi halde asit etkisi ile elektronik komponentler korozyona uğrayabilir Kontrol ünitesi elektrot hücresine en fazla 1 5m uzakta olacak şekilde düşünülmelidir Montaj işlemi için monte edeceğiniz duvarda askı aparatı üzerinden delik yerlerini işaretleyin İşaretlenen yerlere delikler açın dübel...

Страница 19: ...men kuruması beklenmelidir Elektrot haznenin içine doğru yönde oturtulmalıdır Elektrotun açık kısmı su giriş borusu bağlantısına gelecek şekilde olmalıdır Silikon contanın yerinde olduğundan ve sızdırmayacak şekilde yerleştiğinden emin olunmalıdır Elektrot kablosunu kablo boğma contasından ve rakorlu elektrot kafasından geçirerek kablo bağlantı terminallerine bağlayın Rakorlu elektrot kafasını kap...

Страница 20: ... düşürecek yönde etkiler Havuzun suyu aşağıdaki değerleri karşılamalıdır Tuz 5 6 Kg m pH Beton Havuz 7 2 7 6 Polyester 6 8 7 0 TAC 60 100 ppm TH 15 20 Fransız Stabilizör 20 30 ppm veya üreticinin önerisi Sıcaklık 10 C 2 4 Tuz Ekleme Tuz ekleme işlemi sırasında tuzun hepsi çözünene kadar sistem tamamen kapatılmalıdır Tuz tamamen çözünmeden sistemin çalıştırılması durumunda hücre geri döndürülemez h...

Страница 21: ... cihaz kapalı OFF konumdayken 3sn basılı tutulur ve ayar menüsünde sayfalardan ve parametrelerden çıkış fonksiyonlarını gerçekleştirir 3 Ayar menüsündeki sayfalarda ve parametrelerde seçim yapma ayarlanan parametreleri onaylayıp kaydetme fonksiyonlarını gerçekleştirir Çalışma sırasında 3sn basılı tutulması ile cihaz boost moduna geçer ve 8 saat boyunca tam kapasitede çalışır 4 Ayar menüsünde bir ü...

Страница 22: ...amen kireç olarak tabir edilen maddeyle kaplanır Kireç tabakası yalıtkan özellikte olduğundan elektrotlar arası elektrik akışını zorlaştırır Bunun sonucunda klor üretim verimi düşer Elektrotlarda oluşan bu kirecin belli aralıklarla temizlenmesi gerekmektedir Bu temizleme işlemini cihaz polarizasyonu değiştirerek otomatik olarak yapabilme özelliğine sahiptir Polarite peryod sayfası polarizasyon değ...

Страница 23: ...al cihazı örtü moduna geçirir ve ekranda simgesi belirir Cihaz örtülü modda çalışırken istenilen üretim değeri yön butonları ile arttırılıp azaltılır 4 TEMİZLİK BAKIM TALİMATLARI 4 1 Elektrot Temizliği Kullanılan suyun fiziksel özellikleri coğrafi bölgelere göre değişkenlik gösterse de içerisinde mutlaka belli oranlarda kalsiyum magnezyum demir ve diğer mineralleri bulundurması kaçınılmazdır Su so...

Страница 24: ...meye karşı yağlamanız tavsiye edilir Ekipmanı kapatmanız gereken durumlar Hücrede yeterli su olmaması durumunda Filtre temizlenirken Havuz boşaltılırken Su donduğunda Hücre temizlenirken 4 3 Arıza Kodları ve Önerilen Çözüm Yolları Arıza Kodu Muhtemel Arıza Çözüm Yolu ERR1 Kablo kopuk veya temas etmiyor Kabloyu ve bağlantı terminallerini kontrol edin gerekiyorsa değiştirin Elektrot kablo bağlantısı...

Страница 25: ...şına alınır a Ürünün kullanma talimatına aykırı kullanımından doğan arızalar b Yanlış elektrik bağlantılarından doğan arızalar c Çarpma düşme kırma ve benzeri kazalardan doğan arızlar d Kontrol ünitesinde sıvı temasından doğacak arızalar e Bypass devresi bağlantı şemasına uygun olmadan çalışmasından doğacak arızlar f Kontrol ünitesini kapatmadan skimmere asit dökülmesinden kaynaklanan arızalar g M...

Страница 26: ...GEMAŞ Genel Mühendislik Mekanik San veTic A Ş İTOB Organize Sanayi Bölgesi 10001 Sok No 28 Menderes İZMİR TURKEY Tel 0232 799 0 333 Fax 0232 799 0 330 www gemas com tr info gemas com tr 26 ...

Страница 27: ...GEMAŞ Genel Mühendislik Mekanik San veTic A Ş İTOB Organize Sanayi Bölgesi 10001 Sok No 28 Menderes İZMİR TURKEY Tel 0232 799 0 333 Fax 0232 799 0 330 www gemas com tr info gemas com tr 27 ...

Страница 28: ...GEMAŞ Genel Mühendislik Mekanik San veTic A Ş İTOB Organize Sanayi Bölgesi 10001 Sok No 28 Menderes İZMİR TURKEY Tel 0232 799 0 333 Fax 0232 799 0 330 www gemas com tr info gemas com tr 28 ...

Отзывы: