7.4 Product conformities
Machinery Directive:
2006/42/EU
EMC Directive:
2014/30/EU
Interference resistance:
DIN EN 61000-6-2
DIN EN 61326-1 (industrial processes)
Interference emission:
DIN EN 61000-6-4 (Sep. 2011)
Interference emission class: Class A
Interference emission group: Group 1
7.5 Mechanical data
Protection class:
IP 65 acc. to EN 60529
Actuating speed:
Max. 3 mm/s
Stroke:
5 mm
Weight:
Valve body
Connection types
code
Material
code
Weight
1
1
0.1
1
20
0.13
7
1
0.13
Weights in kg
7.6 Duty cycle and service life
Service life:
Control operation -
Class C according to EN 15714-2 (1,800,000 starts and 1200 starts per hour).
Open/Close duty
- At least 500,000 switching cycles at room temperature and permissible duty
cycle.
Duty cycle:
Control module Positioner (code S0, S5, S6), Open/Close duty
0 10 20 30 40 50 60 70
0
10
20
30
40
50
60
70
80
90
100
Duty cycle [%]
Ambient temperature [°C]
NOTICE
▶
The specified characteristics and values apply to the factory setting.
▶
With reduced forces, higher duty cycles and/or higher ambient temperatures are possible. At higher force settings the duty
cycle and/or ambient temperature is reduced.
▶
IO-Link: Index 0x90 - Subindex 2 - Force
www.gemu-group.com
10 / 53
GEMÜ R563