50
Which parameters must be set?
SPH (strokes per hour), SPM (strokes per minute) or LPH (litres per hour).
It is necessary to set if the operating mode of the “Stroke” will have to be “SPH” (strokes per hour), “SPM”
(strokes per minute) or “LPH” (litres per hour).
“LPH” value accuracy depends on cc/st value set in the Setup menu (SET [01] CC/ST).
LPH max value depends on the max frequency of the pump (refer to the pump rating plate). If a higher
value is set, the pump will display an alarm message (ALARM STROKE).
Use “UP” key to choose the mode and “RIGHT” key to change the set value. For next digit (unit) press
again “RIGHT” key.
Press “
P
” key to save the entered value and “
ESC
” to exit to main menu, or press “
ESC
” only to exit
without saving.
Note:
The last mode displayed before pressing “
P
” key will be the active one.
5.2 “DIVIDE” working mode
The impulses supplied by a water meter connected to the pump are divided by the value set during
programming. The pump doses with a frequency set by this parameter.
mode ( 01 )
CONSTANT
CONSTANT
100 spm
CONSTANT
01 sph
CONSTANT
110.0 lph
CONSTANT
11.00 lph
CONSTANT
1.100 lph
Tasto
Tasto
Tasto
Tasto
Tasto
Tasto
Key
Key
Key
Key
Key
Key