118
AFE200 • Instruction Manual
If set to
2
the datum is assigned a 32-bit count.
If set to
3
16 bits on the channel are reserved for the datum, not used.
If set to
4
32 bits on the channel are reserved for the datum, not used.
If set to
5
the datum is assigned a 16-bit count used by MDPLC.
If set to
6
the datum is assigned a 32-bit count used by MDPLC.
If set to
7
the datum is assigned engineering units on a 16-bit integer.
If set to
8
the datum is assigned engineering units on a 32-bit integer.
If set to
9
, the datum is assigned a 16-bit integer engineering unit format not in real
time (5-10ms)
If set to
10
the datum is assigned a 32-bit integer engineering unit format or float for-
mat if the associated parameter is a float-type parameter not in real time (5-10ms)
Note!
If the
sys
parameter is not assigned, none of the subsequent channels are transferred to the fieldbus,
even if programmed.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
14.4.3
4184 Dig Fieldbus S->M1
INT32
32
0
0
0
ERW
14.4.7
4194 Dig Fieldbus S->M2
INT32
32
0
0
0
ERW
14.4.11 4204 Dig Fieldbus S->M3
INT32
32
0
0
0
ERW
14.4.15 4214 Dig Fieldbus S->M4
INT32
32
0
0
0
ERW
14.4.19 4224 Dig Fieldbus S->M5
INT32
32
0
0
0
ERW
14.4.23 4234 Dig Fieldbus S->M6
INT32
32
0
0
0
ERW
14.4.27 4244 Dig Fieldbus S->M7
INT32
32
0
0
0
ERW
14.4.31 4254 Dig Fieldbus S->M8
INT32
32
0
0
0
ERW
14.4.35 4264 Dig Fieldbus S->M9
INT32
32
0
0
0
ERW
14.4.39 4274 Dig Fieldbus S->M10
INT32
32
0
0
0
ERW
14.4.43 4284 Dig Fieldbus S->M11
INT32
32
0
0
0
ERW
14.4.47 4294 Dig Fieldbus S->M12
INT32
32
0
0
0
ERW
14.4.51 4304 Dig Fieldbus S->M13
INT32
32
0
0
0
ERW
14.4.55 4314 Dig Fieldbus S->M14
INT32
32
0
0
0
ERW
14.4.59 4324 Dig Fieldbus S->M15
INT32
32
0
0
0
ERW
14.4.63 4334 Dig Fieldbus S->M16
INT32
32
0
0
0
ERW
If associated with the relative
src
, the value of this parameter is sent to the bus.
The user may modify the
M->S
and by
S->M sys
parameters. The consistency of the
sys with the parameter assigned to the channel is checked.
Check for channels S->M:
Sys parameter
FB type
result
Count 32
32 bit
Sends all 32 bits of input to fieldbus. OK
16_H
Sends all 32 bits of input to fieldbus. OK
16_L
Sends all 32 bits of input to fieldbus. OK
Count 16
32 bit
Doesn’t know whether to send 16H or 16L. Error
16_H
Sends all 16H bits of input to fieldbus. OK
16_L
Sends all 16L bits of input to fieldbus. OK
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
14.4.4
4186 Fieldbus S->M1 mul
FLOAT
1.0
1.0
1000.0 ERW