AFE200 • Instruction Manual
Appendix 2 - Parallel connection (400 ... 1650kW sizes)
A 2.1 Introduction
To obtain an AFE of more than 355 kW connect a number of single units of be
-
tween 200 kW and 355 kW in parallel.
A parallel connection of several units basically consists of one MASTER unit and
one or more SLAVE units.
Power
code
Description (Designation)
Power
code
Description (Designation)
400kW
S9AF21M
AFE200-72000-KXX-4-MS 04
400kW
S9AF51M
AFE200-72000-KXX-6-MS 04
S9AF21S
AFE200-72000-XXX-4-SL
S9AF51S
AFE200-72000-XXX-6-SL
500kW
S9AF22M
AFE200-72500-KXX-4-MS 05
500kW
S9AF52M
AFE200-72500-KXX-6-MS 05
S9AF22S
AFE200-72500-XXX-4-SL
S9AF52S
AFE200-72500-XXX-6-SL
630kW
S9AF23M
AFE200-73150-KXX-4-MS 06
630kW
S9AF53M
AFE200-73150-KXX-6-MS 06
S9AF23S
AFE200-73150-XXX-4-SL
S9AF53S
AFE200-73150-XXX-6-SL
710kW
S9AF24M
AFE200-73550-KXX-4-MS 07
710kW
S9AF54M
AFE200-73550-KXX-6-MS 07
S9AF24S
AFE200-73550-XXX-4-SL
S9AF54S
AFE200-73550-XXX-6-SL
900kW
S9AF231
AFE200-73150-KXX-4-MS 09
900kW
S9AF53M1
AFE200-73150-KXX-6-MS 09
S9AF23S
AFE200-73150-XXX-4-SL
S9AF53S
AFE200-73150-XXX-6-SL
S9AF23S
AFE200-73150-XXX-4-SL
S9AF53S
AFE200-73150-XXX-6-SL
1MW
S9AF241
AFE200-73550-KXX-4-MS 10
1MW
S9AF54M1
AFE200-73550-KXX-6-MS 10
S9AF24S
AFE200-73550-XXX-4-SL
S9AF54S
AFE200-73550-XXX-6-SL
S9AF24S
AFE200-73550-XXX-4-SL
S9AF54S
AFE200-73550-XXX-6-SL
1.35MW
S9AF54M4
AFE200-73550-KXX-6-MS 14
S9AF54S
AFE200-73550-XXX-6-SL
S9AF54S
AFE200-73550-XXX-6-SL
S9AF54S2
AFE200-73550-XXX-6-SL2
1.65MW
S9AF54M5
AFE200-73550-KXX-6-MS 17
S9AF54S
AFE200-73550-XXX-6-SL
S9AF54S
AFE200-73550-XXX-6-SL
S9AF54S2
AFE200-73550-XXX-6-SL2
S9AF54S2
AFE200-73550-XXX-6-SL2
Master unit
this is the only one to have the regulation card and keypad. It differs from the
standard single unit in that the power section control card (INT-P-ADV) is recon
-
figured to function as MASTER and includes one or more MASTER - SLAVE (INT-
SLAVE) interface cards, one card for each slave that is connected.
The MASTER - SLAVE interface is achieved via a specific signal cable included in
the SLAVE AFE
packaging.
Slave unit
It differs from the standard single unit in that it has a dedicated power section
control card (INT-P-ADV) and there is no regulation card or keypad.
INT-P-ADV-MASTER card
The INT-P-ADV-MASTER card provided with one or more INT-SLAVE cards, acts
as the interface between the R-ADV regulation card and the power section of the
master unit and all the slave units. It also performs the following functions:
•
current signal scaling (via dip switch, factory-set)
•
hardware dead time compensation
•
alarm signal management (including local diagnostics via LED)
•
temperature signal management.
Содержание AFE200 4 Series
Страница 94: ...94 AFE200 Instruction Manual 7 DIGITAL INPUTS ...
Страница 97: ... AFE200 Instruction Manual 97 8 DIGITAL OUTPUTS ...
Страница 202: ...202 AFE200 Instruction Manual Appendix 3 Block Diagrams System Diagrams Index Drive overview Reference ...
Страница 203: ... AFE200 Instruction Manual 203 Commands ...
Страница 204: ...204 AFE200 Instruction Manual Digital inputs ...
Страница 205: ... AFE200 Instruction Manual 205 Digital outputs ...
Страница 206: ...206 AFE200 Instruction Manual Analog inputs ...
Страница 207: ... AFE200 Instruction Manual 207 ...
Страница 208: ...208 AFE200 Instruction Manual Analog outputs ...
Страница 209: ... AFE200 Instruction Manual 209 Current Control ...
Страница 210: ...210 AFE200 Instruction Manual Active Curr Config ...
Страница 211: ... AFE200 Instruction Manual 211 Functions ...
Страница 212: ......
Страница 213: ......