Not assigned
1
Count 16
2
Count 32
3
Fill 16
4
Fill 32
5
Mdplc 16
6
Mdplc 32
7
EU
8
Eu float
9
Par 16
10
Par 32
If set to
0
the channel is not assigned.
If set to
1
the datum is assigned a 16-bit count.
If set to
2
the datum is assigned a 32-bit count.
If set to
3
16 bits on the channel are reserved for the datum, not used.
If set to
4
32 bits on the channel are reserved for the datum, not used.
If set to
5
the datum is assigned a 16-bit count used by MDPLC.
If set to
6
the datum is assigned a 32-bit count used by MDPLC.
If set to
7
the datum is assigned engineering units on a 16-bit integer.
If set to
8
the datum is assigned engineering units on a 32-bit integer.
If set to
9
, the datum is assigned a 16-bit integer engineering unit format not in real
time (5-10ms)
If set to
10
the datum is assigned a 32-bit integer engineering unit format or float for
-
mat if the associated parameter is a float-type parameter not in real time (5-10ms)
Note!
If the
sys
parameter is not assigned, none of the subsequent fieldbus channels are read, even if
programmed.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
14.3.3
4024 Fieldbus M->S1 mon
INT32
32
0
0
0
ER
14.3.7
4034 Fieldbus M->S2 mon
INT32
32
0
0
0
ER
14.3.11 4044 Fieldbus M->S3 mon
INT32
32
0
0
0
ER
14.3.15 4054 Fieldbus M->S4 mon
INT32
32
0
0
0
ER
14.3.19 4064 Fieldbus M->S5 mon
INT32
32
0
0
0
ER
14.3.23 4074 Fieldbus M->S6 mon
INT32
32
0
0
0
ER
14.3.27 4084 Fieldbus M->S7 mon
INT32
32
0
0
0
ER
14.3.31 4094 Fieldbus M->S8 mon
INT32
32
0
0
0
ER
14.3.35 4104 Fieldbus M->S9 mon
INT32
32
0
0
0
ER
14.3.39 4114 Fieldbus M->S10 mon
INT32
32
0
0
0
ER
14.3.43 4124 Fieldbus M->S11 mon
INT32
32
0
0
0
ER
14.3.47 4134 Fieldbus M->S12 mon
INT32
32
0
0
0
ER
14.3.51 4144 Fieldbus M->S13 mon
INT32
32
0
0
0
ER
14.3.55 4154 Fieldbus M->S14 mon
INT32
32
0
0
0
ER
14.3.59 4164 Fieldbus M->S15 mon
INT32
32
0
0
0
ER
14.3.63 4174 Fieldbus M->S16 mon
INT32
32
0
0
0
ER
The value received from the bus is displayed. This parameter must be associated with
the src parameter to enable the
M->S
channel.
The user may modify the
M->S
and by
S->M sys
parameters. The consistency of the
sys with the parameter assigned to the channel is checked.
Check for channels M->S:
Содержание AFE200 4 Series
Страница 94: ...94 AFE200 Instruction Manual 7 DIGITAL INPUTS ...
Страница 97: ... AFE200 Instruction Manual 97 8 DIGITAL OUTPUTS ...
Страница 202: ...202 AFE200 Instruction Manual Appendix 3 Block Diagrams System Diagrams Index Drive overview Reference ...
Страница 203: ... AFE200 Instruction Manual 203 Commands ...
Страница 204: ...204 AFE200 Instruction Manual Digital inputs ...
Страница 205: ... AFE200 Instruction Manual 205 Digital outputs ...
Страница 206: ...206 AFE200 Instruction Manual Analog inputs ...
Страница 207: ... AFE200 Instruction Manual 207 ...
Страница 208: ...208 AFE200 Instruction Manual Analog outputs ...
Страница 209: ... AFE200 Instruction Manual 209 Current Control ...
Страница 210: ...210 AFE200 Instruction Manual Active Curr Config ...
Страница 211: ... AFE200 Instruction Manual 211 Functions ...
Страница 212: ......
Страница 213: ......