128
AFE200 • Instruction Manual
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
14.2.8
5608 IP address
UINT32
0
0
4294967295
ER
Display of DCP address set via configuration of Profinet node.
14.3 - COMMUNICATION/FIELDBUS M2S
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
14.3.1
4020 Fieldbus M->S1 ipa
FBM2SIPA
0
0
0
R
14.3.5
4030 Fieldbus M->S2 ipa
FBM2SIPA
0
0
0
R
14.3.9
4040 Fieldbus M->S3 ipa
FBM2SIPA
0
0
0
R
14.3.13 4050 Fieldbus M->S4 ipa
FBM2SIPA
0
0
0
R
14.3.17 4060 Fieldbus M->S5 ipa
FBM2SIPA
0
0
0
R
14.3.21 4070 Fieldbus M->S6 ipa
FBM2SIPA
0
0
0
R
14.3.25 4080 Fieldbus M->S7 ipa
FBM2SIPA
0
0
0
R
14.3.29 4090 Fieldbus M->S8 ipa
FBM2SIPA
0
0
0
R
14.3.33 4100 Fieldbus M->S9 ipa
FBM2SIPA
0
0
0
R
14.3.37 4110 Fieldbus M->S10 ipa
FBM2SIPA
0
0
0
R
14.3.41 4120 Fieldbus M->S11 ipa
FBM2SIPA
0
0
0
R
14.3.45 4130 Fieldbus M->S12 ipa
FBM2SIPA
0
0
0
R
14.3.49 4140 Fieldbus M->S13 ipa
FBM2SIPA
0
0
0
R
14.3.53 4150 Fieldbus M->S14 ipa
FBM2SIPA
0
0
0
R
14.3.57 4160 Fieldbus M->S15 ipa
FBM2SIPA
0
0
0
R
14.3.61 4170 Fieldbus M->S16 ipa
FBM2SIPA
0
0
0
R
Setting of the parameter to associate with the bus channel. The default setting is
0
,
which means channel not active.
If the parameter to be connected is a
sorg
(source), the channel and parameter can
also be associated by modifying the
sorg
parameter in its menu.
When setting a parameter, the format is also automatically set in the sys parameter.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
14.3.2
4022 Fieldbus M->S1 sys
ENUM
Not assigned 0
10
RW
14.3.6
4032 Fieldbus M->S2 sys
ENUM
Not assigned 0
10
RW
14.3.10 4042 Fieldbus M->S3 sys
ENUM
Not assigned 0
10
RW
14.3.14 4052 Fieldbus M->S4 sys
ENUM
Not assigned 0
10
RW
14.3.18 4062 Fieldbus M->S5 sys
ENUM
Not assigned 0
10
RW
14.3.22 4072 Fieldbus M->S6 sys
ENUM
Not assigned 0
10
RW
14.3.26 4082 Fieldbus M->S7 sys
ENUM
Not assigned 0
10
RW
14.3.30 4092 Fieldbus M->S8 sys
ENUM
Not assigned 0
10
RW
14.3.34 4102 Fieldbus M->S9 sys
ENUM
Not assigned 0
10
RW
14.3.38 4112 Fieldbus M->S10 sys
ENUM
Not assigned 0
10
RW
14.3.42 4122 Fieldbus M->S11 sys
ENUM
Not assigned 0
10
RW
14.3.46 4132 Fieldbus M->S12 sys
ENUM
Not assigned 0
10
RW
14.3.50 4142 Fieldbus M->S13 sys
ENUM
Not assigned 0
10
RW
14.3.54 4152 Fieldbus M->S14 sys
ENUM
Not assigned 0
10
RW
14.3.58 4162 Fieldbus M->S15 sys
ENUM
Not assigned 0
10
RW
14.3.62 4172 Fieldbus M->S16 sys
ENUM
Not assigned 0
10
RW
Setting of the format of the datum received on the channel. When the
src
parameter
is programmed, the format is automatically programmed on the relative
sys
. If the
src
parameter is reset to
null
, the format does not change. The value of the format can be
selected from the following list, according to the parameter selected as the source:
Содержание AFE200 4 Series
Страница 94: ...94 AFE200 Instruction Manual 7 DIGITAL INPUTS ...
Страница 97: ... AFE200 Instruction Manual 97 8 DIGITAL OUTPUTS ...
Страница 202: ...202 AFE200 Instruction Manual Appendix 3 Block Diagrams System Diagrams Index Drive overview Reference ...
Страница 203: ... AFE200 Instruction Manual 203 Commands ...
Страница 204: ...204 AFE200 Instruction Manual Digital inputs ...
Страница 205: ... AFE200 Instruction Manual 205 Digital outputs ...
Страница 206: ...206 AFE200 Instruction Manual Analog inputs ...
Страница 207: ... AFE200 Instruction Manual 207 ...
Страница 208: ...208 AFE200 Instruction Manual Analog outputs ...
Страница 209: ... AFE200 Instruction Manual 209 Current Control ...
Страница 210: ...210 AFE200 Instruction Manual Active Curr Config ...
Страница 211: ... AFE200 Instruction Manual 211 Functions ...
Страница 212: ......
Страница 213: ......