AFE200 • Instruction Manual
131
14.4.37 4270 Fieldbus S->M10 ipa
FBM2SIPA
0
0
20000 RW
14.4.41 4280 Fieldbus S->M11 ipa
FBM2SIPA
0
0
20000 RW
14.4.45 4290 Fieldbus S->M12 ipa
FBM2SIPA
0
0
20000 RW
14.4.49 4300 Fieldbus S->M13 ipa
FBM2SIPA
0
0
20000 RW
14.4.53 4310 Fieldbus S->M14 ipa
FBM2SIPA
0
0
20000 RW
14.4.57 4320 Fieldbus S->M15 ipa
FBM2SIPA
0
0
20000 RW
14.4.61 4330 Fieldbus S->M16 ipa
FBM2SIPA
0
0
20000 RW
Setting of the parameter to associate with the bus channel. The default setting is
0
,
which means channel not active.
When setting a parameter, the format is also automatically set in the
sys
parameter
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
14.4.2
4182 Fieldbus S->M1 sys
ENUM
Not assigned 0
10
RW
14.4.6
4192 Fieldbus S->M2 sys
ENUM
Not assigned 0
10
RW
14.4.10 4202 Fieldbus S->M3 sys
ENUM
Not assigned 0
10
RW
14.4.14 4212 Fieldbus S->M4 sys
ENUM
Not assigned 0
10
RW
14.4.18 4222 Fieldbus S->M5 sys
ENUM
Not assigned 0
10
RW
14.4.22 4232 Fieldbus S->M6 sys
ENUM
Not assigned 0
10
RW
14.4.26 4242 Fieldbus S->M7 sys
ENUM
Not assigned 0
10
RW
14.4.30 4252 Fieldbus S->M8 sys
ENUM
Not assigned 0
10
RW
14.4.34 4262 Fieldbus S->M9 sys
ENUM
Not assigned 0
10
RW
14.4.38 4272 Fieldbus S->M10 sys
ENUM
Not assigned 0
10
RW
14.4.42 4282 Fieldbus S->M11 sys
ENUM
Not assigned 0
10
RW
14.4.46 4292 Fieldbus S->M12 sys
ENUM
Not assigned 0
10
RW
14.4.50 4302 Fieldbus S->M13 sys
ENUM
Not assigned 0
10
RW
14.4.54 4312 Fieldbus S->M14 sys
ENUM
Not assigned 0
10
RW
14.4.58 4322 Fieldbus S->M15 sys
ENUM
Not assigned 0
10
RW
14.4.62 4332 Fieldbus S->M16 sys
ENUM
Not assigned 0
10
RW
When setting the sorg parameter the format is automatically set on the relative
sys
.
If sorg is set to
null
, the data format does not change. The value of the format can be
selected from the following list, according to the parameter selected as the source:
0
Not assigned
1
Count 16
2
Count 32
3
Fill 16
4
Fill 32
5
Mdplc 16
6
Mdplc 32
7
EU
8
Eu float
9
Par 16
10
Par 32
If set to
0
the channel is not assigned.
If set to
1
the datum is assigned a 16-bit count.
If set to
2
the datum is assigned a 32-bit count.
If set to
3
16 bits on the channel are reserved for the datum, not used.
If set to
4
32 bits on the channel are reserved for the datum, not used.
If set to
5
the datum is assigned a 16-bit count used by MDPLC.
If set to
6
the datum is assigned a 32-bit count used by MDPLC.
If set to
7
the datum is assigned engineering units on a 16-bit integer.
If set to
8
the datum is assigned engineering units on a 32-bit integer.
If set to
9
, the datum is assigned a 16-bit integer engineering unit format not in real
time (5-10ms)
Содержание AFE200 4 Series
Страница 94: ...94 AFE200 Instruction Manual 7 DIGITAL INPUTS ...
Страница 97: ... AFE200 Instruction Manual 97 8 DIGITAL OUTPUTS ...
Страница 202: ...202 AFE200 Instruction Manual Appendix 3 Block Diagrams System Diagrams Index Drive overview Reference ...
Страница 203: ... AFE200 Instruction Manual 203 Commands ...
Страница 204: ...204 AFE200 Instruction Manual Digital inputs ...
Страница 205: ... AFE200 Instruction Manual 205 Digital outputs ...
Страница 206: ...206 AFE200 Instruction Manual Analog inputs ...
Страница 207: ... AFE200 Instruction Manual 207 ...
Страница 208: ...208 AFE200 Instruction Manual Analog outputs ...
Страница 209: ... AFE200 Instruction Manual 209 Current Control ...
Страница 210: ...210 AFE200 Instruction Manual Active Curr Config ...
Страница 211: ... AFE200 Instruction Manual 211 Functions ...
Страница 212: ......
Страница 213: ......