2. Driving End Frame Assy.: The driving end frame is used to support the rotor with which the alternator is mounted on the
engine. In order to improve the cooling performance of the alternator. The ventilating hole is on the rear cover and front
cover.
3. Stator Assy.: It includes stator iron core and stator winding, which is pressed into the driving end frame to form an integral
part.
4. Rectifier Assy.: The diode of the rectifier applies a connection pole for insulation, which makes the rectifier a whole assy.
characterized by compact structure, small size and reliable performance. It is fixed behind the rear end frame with screws.
5. Voltage Regulator: It is secured behind the rear end frame of the alternator with screws whose interior is composed of a
single IC board. The voltage regulator is small in size and reliable in performance.
Furthermore, the charging indication light indicates the working status of the generator and reminds the driver of not forget-
ting switching off the ignition switch to prevent the battery from discharging to the generator.
1. Rotor Winding Check: The open circuit or short circuit malfunction of the rotor winding can be checked by measur-
ing the resistance. During checking, shown in the Fig. 361, place the multimeter in the position Rx1, connect the two
rods with the two collector rings and view the instrument readings (standard value is 2.7—3.1Ω).
2. Rotor Shaft Bending Check: The axial vibration shall not exceed 0.5mm; if it exceeds this value, the rotor shall be put in
the V block or placed in the lathe for correction. If necessary, replace the
rotor assy.
3. Armature winding check (Fig. 362): The open circuit malfunction of the
armature winding can be checked by the R×1 of the multi-meter. When
checking, connect the two rods with any two of the wires of the armature
winding, the circuit shall be connected. If the value is infinity, it indicates an
open circuit somewhere in the winding. The earthing malfunction of the
armature can be checked by the R×1K of the multimeter. While checking,
connect one rod with the iron core of the stator while connecting the other
with each outlet wire. If the reading is infinity, the armature winding is good
in insulation; if the reading is zero, there is earthing in the armature
winding.
4. Rectifier check: Check with R×1K of the multimeter. Connect one pen to
the terminal B and the other one to the terminal E. If the circuit is connected
in one direction, while unconnected after exchanging the positions of two
pens, the rectifier functions well. Otherwise, the rectifier is proven to have
malfunction and needs replacement.
Carbon brush and brush holder shall be neat and tidy without damage or
crack. The valid exposed length of the carbon brush after being installed
shall be 4.5mm. If excessive wear reduces the length to less than 2/3 of the
original, it needs replacement.
II. Alternator Check
The alternator socket must be installed firmly to prevent the alternator from producing transient over high voltage due to
a loosened socket and B terminal, followed by a burning of the diode and electric equipment.
III. Alternator Application and Maintenance
Fig. 361 Rotor Winding Check
Fig. 362 Armature winding check
174
Содержание JL481Q
Страница 1: ......
Страница 9: ...5 Fig 3 Components Assembly Drawing of MR479Q MR479QA Engine ...
Страница 10: ...6 Fig 4 MR479Q MR479QA Engine and Its Power System ...
Страница 11: ...7 Fig 5 Assembly Drawing of Engine and Its Auxiliaries MR479Q MR479QA ...
Страница 12: ...8 Fig 6 Electronic Control Fuel Injection System in Engine MR479Q MR479QA ...
Страница 13: ...9 Fig 7 Front view of Engine JL481Q MR481QA ...
Страница 14: ...10 Fig 8 Sectional elevation of Engine JL481Q MR481QA ...
Страница 15: ...11 Fig 9 Electronic Control Fuel Injection System in Engine JL481Q MR481QA ...
Страница 21: ...17 Fig 13 Exterior Feature of JL481Q Engine Power Me N m Torque Pe Kw ge g kwh Fuel Consumption Ratio ...