Description
Default setting
7160-9001-560
01. December 2020
3.1
Technical Data
Environment/thermal data (VP8002)
Operating temperature
-10 - 45 ºC [14 -113 ºF]
Transport and storage temperature
-25 - 70 ºC [-13 -158 ºF]
Relative humidity
10-93%
Electrical specifications (VP8002)
Input voltage range
25 VDC,+10% ,-10%
Output voltage
25 VDC,+10% ,-10%
Power consumption
300mA
Short-circuit protected (power supply)
Inputs
2x digital
Outputs
2 x (250 mA)
2 x (4 A - CAN-Bus)
CAN bus communication
125 kbit/s,2 channels
Communication
Ethernet LAN 100/10 Mbps
Firmware / Software
downloadable
Protection class
IP20
Internal power supply
Maximum current
2 A
Housing (7159-2853-050)
Protection rating
IP 65
Geometric data
lengthxWidthxElevation
(without mounting rail)
143 x 127 x 68 mm
weight
400 g
3.2
Default setting
Other settings can be used.
For more information on this subject, please refer to the section on
Commissioning
Important!
Incorrect settings can have a negative effect on the health of the animals,
the quality of the milk and milking results.
► Changes may only be carried out by trained personnel.
► Check all factory settings before commissioning and adjust to the
individual requirements of the installation or animal if necessary.