9.5.6 Dismantling the valve insert into individual parts
Tools
●
Belt wrench
●
Jaw wrench a/f 10
●
Jaw wrench a/f 13
●
Jaw wrench a/f 17
●
Jaw wrench a/f 21
●
Jaw wrench a/f 23
1.
Loosen the clamp connection (46) be-
tween the actuator and the lantern.
®
The lantern can be turned to al-
low the jaw wrench to be posi-
tioned to release the lock nut
(10).
2.
Hold the lock nut (10) tight on the
wrench flat surface (10.1) with a jaw
wrench.
3.
Turn the actuator with a belt wrench
and release the valve disk (15).
10.1
10
46
15
62 / 104 - 9.5 Removing the valve
0000000881 - 001 - EN-GB
Содержание VARIVENT X R Series
Страница 1: ...Operating Instructions Hygienic valves GEA VARIVENT Shuttle valve type X_R 2023 03 430BAL015128EN...
Страница 9: ...1 4 Declarations of conformity 1 4 Declarations of conformity 9 104...
Страница 12: ...12 104 1 4 Declarations of conformity 0000000881 001 EN GB...
Страница 40: ...40 104 5 5 Checking the pneumatic connection 0000000881 001 EN GB...
Страница 44: ...44 104 7 3 Shutdown 0000000881 001 EN GB...
Страница 88: ...88 104 9 7 Maintenance 0000000881 001 EN GB...
Страница 90: ...90 104 9 7 Maintenance 0000000881 001 EN GB...
Страница 98: ...98 104 12 2 Spare parts lists 0000000881 001 EN GB...
Страница 103: ...13 2 List of abbreviations 103 104...