Spring-to-close valve (NC) with control top T.VIS
INFO
Mounting step: mount the clamp connection between the housing and
lantern
Tools
●
Jaw wrench a/f 10
●
Jaw wrench a/f 13
●
Torque wrench ¼“ 2,5-25 Nm
●
Socket for wrench ¼" long a/f10
●
Socket for wrench ¼" a/f13
1.
Pressurize the actuator with compressed air, max. 8 bar, by activating solenoid valve
Y1 at the manual operation element S.
®
Valve disk is raised.
Valve insert lowers into the seat.
2.
Mount the clamp connection (43) between the housing and lantern.
®
Observe torques, see
.
3.
Depressurize the actuator - 0 bar - by deactivating the solenoid valve Y1 at the
manual operation element S.
®
The valve disk is lowered.
74 / 104 - 9.6 Installing the valve