9.5.7 Dismantling of the housing combination
Prerequisites
●
This housing combination does not exist for welded housings
Tools
●
Jaw wrench a/f10
●
Jaw wrench a/f 13
1.
Remove the clamp connections (43)
on the housing combination.
2.
Remove the blanking plate (35).
3.
Remove the seat rings (33)
33
35
43
43
Þ
Housing combination is dismantled.
All seals are freely accessible.
9.6 Installing the valve
9.6.1 Tightening torques
Tighten the following valve connections to the torques specified in the table.
Tightening torques
[Nm]
[lbft]
Valve disk
M14
80
59
Spacer nut
M14
80
59
INI holder
M34
60
44.2
Switch bar
M14
2
1.5
Clamps on the control top
M14
1
0.7
Cap
1
0.7