9.6.3 Assembly of the housing combination
Prerequisites
●
loose housing combination available
Tools
●
Jaw wrench a/f 10
●
Jaw wrench a/f 13
●
Torque wrench ¼“ (2.5-25 Nm)
●
Socket for wrench ¼" long a/f 10
●
Socket for wrench ¼" a/f 13
1.
Place the seat rings (33) with the O-
ring (5) into the housing and mount
the clamp connection (43).
®
Observe torques, see table ‘Tight-
ening torques’.
2.
Place the blanking plate (35) with the
O-ring (5) into the housing and
mount the clamp connection (43).
®
Observe torques, see table ‘Tight-
ening torques’.
5
33
5
5
5
5
35
43
33
43
43
Þ
Housing combination is assembled.
68 / 104 - 9.6 Installing the valve