Spring-to-close valve (NC) without control top T.VIS
INFO
Mounting step: mount the clamp connection between the housing and
lantern
Tools
●
Jaw wrench a/f 10
●
Jaw wrench a/f 13
●
Torque wrench ¼“ 2,5-25 Nm
●
Socket for wrench ¼" long a/f 10
●
Socket for wrench ¼" a/f 13
1.
Pressurize the actuator - with compressed air, max. 8 bar - connection 0.
®
Valve disk is raised.
Valve insert lowers into the seat.
2.
Mount the clamp connection (43) between the housing and lantern.
®
Observe torques, see
.
3.
Depressurize actuator (connection 0).
®
The valve disk is lowered.
43
76 / 104 - 9.6 Installing the valve
0000000881 - 001 - EN-GB
Содержание VARIVENT X R Series
Страница 1: ...Operating Instructions Hygienic valves GEA VARIVENT Shuttle valve type X_R 2023 03 430BAL015128EN...
Страница 9: ...1 4 Declarations of conformity 1 4 Declarations of conformity 9 104...
Страница 12: ...12 104 1 4 Declarations of conformity 0000000881 001 EN GB...
Страница 40: ...40 104 5 5 Checking the pneumatic connection 0000000881 001 EN GB...
Страница 44: ...44 104 7 3 Shutdown 0000000881 001 EN GB...
Страница 88: ...88 104 9 7 Maintenance 0000000881 001 EN GB...
Страница 90: ...90 104 9 7 Maintenance 0000000881 001 EN GB...
Страница 98: ...98 104 12 2 Spare parts lists 0000000881 001 EN GB...
Страница 103: ...13 2 List of abbreviations 103 104...