Tools
●
Belt wrench
●
Jaw wrench a/f 10
●
Jaw wrench a/f 13
●
Jaw wrench a/f 17
●
Jaw wrench a/f 21
●
Jaw wrench a/f 23
●
Ring wrench double-open size 21x23
ATTENTION
Sensitive sealing surfaces in the actuator
The sealing surfaces on the cylinder can become damaged.
●
Take care no dirt enters the actuator.
1.
Push the lantern (9) onto the actuator
(A).
2.
Push the bearing disk (4) with bearing
(2) and seal disk (3) with seal ring (1)
onto the valve disk (15).
3.
Screw the lock nut (10) to the valve
disk (15) using 2 jaw wrenches.
®
Observe torques, see table ‘Tight-
ening torques’.
3
4
1
2
9
A
15
10
66 / 104 - 9.6 Installing the valve
0000000881 - 001 - EN-GB