Function Default
Description
Auto phone test
Off
Determines whether the panel automatically performs a
periodic phone test (on), or not (off). The test interval can be
from 001 to 254 days. The time of day the panel performs the
test is determined by the supervisory time, which must be
turned on for this feature to work.
Supervisory time
12:00am
Determines when the panel reports supervisory conditions
(sensor failures) and automatic phone tests to the central
station. The panel clock must be set to the correct time for this
option and the automatic phone test to work correctly.
Alarm cancel
006 minutes
Sets the time frame that determines whether the panel reports
an alarm cancel message to the central station. If the system is
disarmed from an alarm state within the programmed time,
the panel sends an alarm cancel message to the central
station. An alarm cancel message is not reported if the system
is disarmed after the programmed time expires.
The time can be set from 006 to 255 minutes. When set to 255,
the panel always reports alarm cancel messages. Turning off
this option disables alarm cancel reporting.
RF time-out
12 hours
Determines the period during which the panel must receive at
least one supervisory signal from learned sensors before
identifying a sensor failure and sounding trouble beeps. Any
sensor failure is reported immediately and again at the
supervisory time. The timeout can be set from 02 to 36 hours.
Entries must be two digits.
Fail-to-open time
Off
Determines whether the panel sends a fail-to-open report to a
central station if the system has not been disarmed by the
programmed time (on), or not (off). System time must be set
correctly for this feature to work.
Fail-to-close time
Off
Determines whether the panel sends a fail-to-close report to a
central station if the system has not been armed by the
programmed time (on), or not (off). System time must be set
correctly for this feature to work.
Siren time-out
005 minutes
Determines how long sirens sound alarms if no one is present
to disarm the system. The time can be set from 002 to 254
minutes. When this feature is turned off, sirens sound alarms
until the alarm is canceled (system disarmed).
Arm LED shutdown Off
Determines whether the panels LEDs (buttons) turn off 30
seconds after the last button press (on), or remain on for the
entire arming period (off).
Unvacated premises On
Determines whether the system automatically arms down to
level 2 (doors and windows) if you arm the system to level 4
(doors, windows, and motion sensors) without leaving the
premises (on), or remains at the armed level chosen (off). This
feature does not work from a key fob. Autobypass must be on
for this feature to work.
36
Simon XT Installation Manual
Содержание SIMON XT
Страница 1: ...Simon XT Installation Manual P N 466 2265 02 REV C ISS 01FEB11 ...
Страница 63: ......