Type
Name/application
Siren type
Dela
y
Restoral
Supervised
Active in
arming
levels
24 Local instant auxiliary: 24-hour local alarm zone
protecting anything that opens and closes. Sirens shut
off at restoral. No report.
Emergency I Y Y 01234
25 Local special chime: Notify the user when a door is
opened.
Three beeps I
N Y
01234
26 Fire: 24-hour fire, rate-of-rise heat, and smoke sensor.
Fire
I
Y Y
01234
27 Lamp control or other customer feature. No report.
Silent
I
Y Y
01234
28 PIR motion sensor, sound sensor, or pressure mat. RF
thermostat. No report
Silent I
N
Y
01234
29 Auxiliary:
Freeze
sensor.
Trouble
beeps
I Y Y 01234
32 PIR motion sensor or sound sensor. No report.
Silent
I
N N
01234
34 Carbon
monoxide
alarm.
Emergency I Y Y 01234
35 Entry/exit delay interior PIR motion
Intrusion
S N Y
234
36 Special intrusion: Such as gun cabinets and wall safes.
Reports as tamper if tripped.
Intrusion I
Y
Y
1234
38 Auxiliary:
Water
sensor.
Trouble
beeps
I Y Y 01234
39 Local instant interior: 24-hour local alarm zone
protecting anything that opens and closes. No report.
Intrusion I
Y
Y
1234
40 Local special chime.
Three beeps I
Y Y
01234
43 Property/asset management: Notify the user that a
protected asset has moved.
Note: We recommend you use this sensor group in
combination with a Two-Way Talking Touch Screen.
One beep
I
N Y
01234
Simon XT Installation Manual