Function Default
Description
Trouble beeps
On
Determines whether the panel and hardwired interior sirens
sound six beeps every minute when a trouble condition occurs
(on), or not (off). The following conditions cause trouble beeps: AC
power failure (when AC power failure report is on) low CPU
battery, sensor failure (supervisory), sensor trouble (low battery,
tamper, etc.), fail to communicate, restoration of power, no
activity timer has timed out (trouble beeps continue for 5 minutes
and if the panel does not see activity, trouble beeps stop and the
panel reports no activity to the central station).
You can silence trouble beeps by arming or disarming the system
or by pressing the STATUS button. Trouble beeps resume later if
the trouble condition is not cleared.
Voice chime
Off
Determines whether the panel announces the sensor name.
1 = sensor name
2 = loud ding-dong bell
3 = soft ding-dong bell
Off = no sound
Status beeps vol
7
Determines the panel piezo volume level for status sounds such
as arming, trouble, and status beeps. Volume range is 1 (lowest)
to 10 (highest).
HW siren sup
Off
Determines whether the panel monitors hardwired sirens for
open conditions (on), or not (off). If this option is turned on, sirens
connected to the panel terminals require an EOL resistor in the
wire circuit. If this option is turned off, EOL resistors are not
required whether sirens are connected or not.
Speaker volume
8
Determines the volume of voice messages from the panel
speaker. Volume range is 1 (lowest) to 8 (highest).
Silent police panic Off
Determines whether pressing the panel police button causes an
audible (off) or silent (on) alarm.
Alarm report
verify
Off
Determines whether the panel verifies successful alarm reports
to the central station by displaying “Phone comm OK” (on), or not
(off).
Simon XT Installation Manual
39