– 39 –
ERC Failure Codes
Failure Codes are accessed by pressing and holding the
HOME and OPTIONS keys simultaneously for 3 seconds.
The LCD screen will show the last 7 failure codes logged
by the system. For a double wall oven, failure codes for
each cavity are displayed independently on the screen.
The clear KEY at the bottom of the screen can be pressed
to clear the failure code log.
The F codes are stored in nonvolatile eeprom
•
memory. They do not show on the display for the
customer.
The last 7 F codes can be recalled by pressing
•
together the HOME and OPTIONS keys for 3 seconds.
All F codes are suppressed.
•
FAILURE
CODE
MEANING
CAUSE / CORRECTION
F2
Oven temperature
inside oven cavity as
measured by sensor
over 650°F unlatched or
915°F latched.
Welded relay contacts on the relay board.
•
Air
fl
ow to rear of unit.
•
High resistance in oven sensor leads and/or connectors (especially at
•
sensor in rear).
F3
Open oven sensor
(over 2900
Ω
)
Disconnect power. Disconnect sensor harness from control. Measure sensor
•
resistance (white leads) to be 1080
Ω
at room temperature with 2
Ω
per
degree change.
Look for damaged harness terminals if not a bad sensor.
•
F4
Shorted oven sensor
(under 950
Ω
)
Disconnect power. Disconnect sensor harness from control. Measure sensor
•
resistance (white leads) to be 1080
Ω
at room temperature with 2
Ω
per
degree change.
Separate sensor from harness to determine fault.
•
F7
Shorted key
Check logic display assembly. If rubber button pad is misaligned, correct;
otherwise, replace control.
F8
EEPROM data shift
failure
If repeated, replace control.
F9
Cooling fan stalls or
other cause of open
thermal switch
Suspect stalled cooling fan or air
fl
ow to control area.
CX
C1
C4
Communication Error
Communication Fail
with Upper Relay Board
Communication Fail
with Lower Relay Board
Check harness
fi
rst and then replace component indicated by Cx Error Code.
FC
Door Latch Error
Inspect door latch and circuitry. Replace if switches are defective.
Last 7 Failure F- Codes :
Upper 7 Fcode Log Lower 7 Fcode Log
C1 F9
F3 CX
F7-S
F3
F7-S
F3
F7-S
CX
F7-S
F3
F7-S
CX
Clear
All