– 55 –
Troubleshooting Notes
Problem
Action
Refrigerator HMI displays a temperature of 80°F
(27°C), even though the temperature in the
refrigerator section is correct.
The HMI may display 80°F (27°C) if the
refrigerator thermistor (air) is either open or
shorted. Run service diagnostics (Test
0 7
) to
confi rm.
Freezer HMI displays -25°F (-32°C), even though
the temperature in the freezer section is correct.
The HMI may display -25°F (-32°C) if the freezer
thermistor (air) is open. Run service diagnostics
(Test
0 7
) to confi rm.
Freezer HMI displays 80°F (27°C), even though
the temperature in the freezer section is correct.
The HMI may display 80°F (27°C) if the freezer
thermistor (air) is shorted. Run service diagnostics
(Test
0 7
) to confi rm.
Unit is dead (except for interior lights). CN1
connector reads 120VAC.
Check the compressor overload. Control board
will not receive voltage if the overload is open.
Ambient air thermistor fails service diagnostics
test. HMI displays open circuit.
Check the thermistor connection behind the HMI
display to see if the pins are pushed out of the
connector.
Содержание Profile PSB42LGRBV
Страница 56: ... 56 Schematics CHOKE PSB42LGRBV PSB42LGRWV PSB42LSRBV PSB48LGRBV PSB48LGRWV PSB48LSRBV Part 1 AC Section ...
Страница 57: ... 57 Schematics Part 2 DC Section ...
Страница 58: ... 58 Illustrated Parts PSB42LSRBV Shown ...
Страница 59: ... 59 PSB42LSRBV Shown ...
Страница 60: ... 60 PSB42LSRBV Shown ...
Страница 61: ... 61 PSB42LSRBV Shown ...
Страница 62: ... 62 PSB42LSRBV Shown ...
Страница 63: ... 63 PSB42LSRBV Shown ...
Страница 64: ... 64 PSB42LSRBV Shown ...
Страница 65: ... 65 PSB42LSRBV Shown ...
Страница 66: ... 66 PSB42LSRBV Shown ...
Страница 67: ... 67 PSB42LSRBV Shown ...