NX-10 Installers manual
179
Segment 2 - House code
Program a number from 0-15 to represent the corresponding house code from the following table.
X-10 Location code (house code)
0=A 4=E 8=I 12=M
1=B 5=F 9=J 13=N
2=C 6=G 10=K 14=O
3=D 7=H 11=L 15=P
LOCATIONS 150-159 - AUTHORIZING USERS 1 - 99 TO TRIGGER OUTPUTS 1 - 8 (10 segments,
feature selection data)
When activating outputs with a user code (event 45), locations 150-159 can be used to restrict certain
codes from activating certain outputs. Each location contains 10 segments. Segment 1 corresponds to
user 1, segment 10 corresponds to user 10. The LED’s correspond to outputs 1 - 8.
Location
Segments
Type
Function
150 10
option
AUTHORIZING USERS 1 - 10 TO TRIGGER OUTPUTS 1 – 8
Segment 1 – user 1, segment 2 – user 2 ….. segment 10 – user 10
151 10
option
AUTHORIZING USERS 11 - 20 TO TRIGGER OUTPUTS 1 – 8
Segment 1 – user 11, segment 2 – user 12 ….. segment 10 – user 20
152
10
option
AUTHORIZING USERS 21 - 30 TO TRIGGER OUTPUTS 1 - 8
153
10
option
AUTHORIZING USERS 31 - 40 TO TRIGGER OUTPUTS 1 - 8
154
10
option
AUTHORIZING USERS 41 - 50 TO TRIGGER OUTPUTS 1 - 8
155
10
option
AUTHORIZING USERS 51 - 60 TO TRIGGER OUTPUTS 1 - 8
156
10
option
AUTHORIZING USERS 61 - 70 TO TRIGGER OUTPUTS 1 - 8
157
10
option
AUTHORIZING USERS 71 - 80 TO TRIGGER OUTPUTS 1 - 8
158
10
option
AUTHORIZING USERS 81 - 90 TO TRIGGER OUTPUTS 1 - 8
159
10
option
AUTHORIZING USERS 91 - 99 TO TRIGGER OUTPUTS 1 - 8
Option
Function
ON
Code will activate Output 1
1
OFF Code
will
NOT
activate output 1
ON
Code will activate Output 2
2
OFF Code
will
NOT
activate output 2
ON
Code will activate Output 3
3
OFF Code
will
NOT
activate output 3
ON
Code will activate Output 4
4
OFF Code
will
NOT
activate output 4
ON
Code will activate Output 5
5
OFF Code
will
NOT
activate output 5
ON
Code will activate Output 6
6
OFF Code
will
NOT
activate output 6
ON
Code will activate Output 7
7
OFF Code
will
NOT
activate output 7
ON
Code will activate Output 8
8
OFF Code
will
NOT
activate output 8
Содержание NX-10