Setting arm schedules
Figure 20. Arm Schedules menu
The control panel can be programmed to automatically disarm (open) and arm (close) partitions at
specified times on specified days. To program auto-arm schedules, you must enable the advanced
menu. Select
Installer Menu>Maintenance Mode>Advanced Menu>Enabled
and press
OK
. Then
select
Installer Menu>Control Panel>Arm Schedules.
Note
: If reports are sent, the user code will be 97 in logs and reports.
Setting up schedules
You can set up a schedule to control the opening and autoarming events for each partition. The
following example sets a schedule for partition 1 so that it is automatically closed at 18.00 on a
Monday if there is no activity in the building. If there is activity at closing time, the control panel will
try to arm after every 45 minutes of inactivity until the next opening time, or until the system is
armed manually.
1.
Ensure the advanced menu is enabled.
2.
Navigate with the
½¾
keys to
Control Panel>Arm Schedules
and press
OK
.
3.
Scroll to
Auto Arm>Partition 1>Sunday
>
Yes
and press
OK
.
4.
The keypad beeps once to accept the change and returns to
Sunday
.
5.
Scroll to
45 Minute Retry
>
Enabled
and press
OK
.
6.
The keypad beeps once to accept the change and returns to
45 Minute Retry
.
Arm Only After Close
(1) Partition 1
Schedule Times
Auto Arm
Closing/Autoarm
Opening
(1) Partition 1
2.7.1
2.7.2
2.7.4
2.7.1.1
2.7.2.1
2.7. .1
4
2.7. .2
4
2.7.1.1.1
2.7.1.1.2
2.7.1.1.3
2.7.1.1.4
2.7.1.1.5
2.7.1.1.6
2.7.1.1.7
2.7.2.1.1
2.7.2.1.2
2.7.2.1.3
2.7.2.1.4
2.7.2.1.5
2.7.2.1.6
2.7.2.1.7
2.7.2.1.8
2.7. .1.1
4
2.7. .1.2
4
2.7. .2.1
4
2.7. .2.2
4
Hour
Minute
Sunday
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Hour
Minute
Sunday
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
45 Minute Retry
Partitions 2 -
Same as above
4
Partitions 2 -
Same as above
4
Auto Disarm
(1) Partition 1
2.7.3
2.7. .1
3
2.7. .1.1
3
2.7. .1.2
3
2.7. .1.3
3
2.7. .1.4
3
2.7. .1.5
3
2.7. .1.6
3
2.7. .1.7
3
Partitions 2 -
Same as above
4
Sunday
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday