NX-10 Installers manual
203
To Do This
Send This
Explanation
Example
Get a list of zones with
problems
zone faults
[
partition list
]
Sends a list of zones with
problems (like tamper, low
battery, zone lost, etc.) to
your phone. Sending a
command without a
partition list returns
information for all partitions.
zone faults 1
to receive fault information
from zones assigned to partition 1
zone faults all
to receive the message
with zone faults for all zones
Bypass zones
bypass
[
zone list
]
Bypasses the specified
zones.
bypass 1 3
to bypass zones 1 and 3
Read events from the event log
events
[
number
]
events
[
range
]
Sends the specified event or
events from the event log to
the phone.
events 1
to read the last (newest) event
from the panel log
events 1 3
to read the last 3 events from
the panel log
events
returns the 10 most recent
events
Set a connection to a home
automation device
output
[
output_number
X10_house_code X10_unit
]
Connects a specified home
automation device.
output 2 A 1
to set output two to control
X-10 device with house code A and unit
number 1
Switch on X-10 outputs
on
[
output list
]
Switches on an X-10 output.
on 1 4 7
to switch on X-10 outputs 1, 4
and 7
on all
to switch on all X-10 outputs
Switch off X-10 outputs
off
[
output list
]
Switches off an X-10 output.
off 1 4 7
to switch off X-10 outputs 1, 4
and 7
off all
to switch off all X-10 outputs
Activate an auxiliary function
switch aux
[
output list
]
Changes the auxiliary
function that occurs when it
is activated, for example by
a button on a keyfob.
switch aux 1
to activate aux output 1 on
the panel
Change your user code
user code
[
new user code
]
Changes your user code.
user code 0101
to change your own
user code to 0101
Change another user code
user code
[
user number new
user code
]
Changes another persons’
user code.
user code 2 0101
to change the user
code to 0101 for the user 2
Delete a user code
delete user code
[
user number
]
Deletes a user code.
delete user code 2
to delete the user
code for the user 2
Start reporting
start reporting
Sends reports from the
NX7002.
start reporting
Stop reporting until system re-
arm
stop reporting
Stops reports being sent
form the NX7002 until the
system is rearmed.
stop reporting
Stop reporting until you start it
again
stop reporting permanent
Stops reports being sent
from the NX7002 until the
start reporting command is
sent.
stop reporting permanent
Register your phone
register
[
phone number user
number
]
The phone is registered with
your alarm system.
register 32444123456 2
to register the
number 32444123456 to user 2
Register your phone with a new
password
register
[
phone number user
number Password
]
The phone is registered with
your alarm system with a
new password.
register 32444123456 1 44aa44
to
register the number 32444123456 to
user 1 with a password 44aa44
To change language
language
[
language
]
The language the SMS texts
use is changed. The
available arguments
(languages) are: English,
Dutch, Espanol, Suomi,
Italiano, Polska, Portugues,
Svenska, Francais, Dansk,
Deutsch and Norsk.
Note:
no national
characters are to be used in
typed arguments.
language deutsch
to change the
interface to German
Содержание NX-10
Страница 1: ...GE Security NX 10 Alarm System Installers Manual 1060789 ...
Страница 10: ...Section A Installing and programming a basic system ...
Страница 244: ...Section C References ...