Special formats
LOCATION 18 - CUSTOM COMMUNICATOR FORMAT (see locations 2, 8, and 14)
Segment 1
1 =
On for 1800hz transmit; Off for 1900hz
2 =
On for 2300hz handshake; Off for 1400hz
3 =
On for checksum parity; Off for double round parity
4 =
On for 2 digit event code; Off for 1 digit event code
5 =
On for extended reporting; Off for non-extended reporting
6
=
Reserved
7 =
On for 20 PPS; Off for 10 or 40 PPS
8 =
On for 10 PPS; Off for 20 or 40 PPS
Segment 2
1 =
On for pager format (no handshake required).
2 =
On for 1400/2300 handshake
3
=
Reserved
4
=
Reserved
5 =
On for Contact ID
6 =
On for SIA
7 =
On for 3 digit event code
8 =
On for DTMF
Segment 3
Reserved
Segment 4
Inter-digit time for pulse format:
The inter-digit time is the value programmed on this location, divided by the pulse-
rate (PPS) of the programmed format. This is programmed in a binary way: in order to
program the value “10”, options 2 and 4 must be selected, for value “5”, options 1
and 3 must be selected.
Ex: when the value 10 is programmed on segment 4 and a pulse format of 20 PPS is
used, the inter-digit time is 10/20 = 0.5 sec.
Download parameters
LOCATION 19 - DOWNLOAD ACCESS CODE (8 segments, numerical data)
Location 19 contains the eight-digit access code that the NX-10 must receive from the downloading
software before the panel will allow downloading. The factory default code is 84800000.
LOCATION 20 - NUMBER OF RINGS TO ANSWER (1 segment, numerical data)
Location 20 contains the number of rings to answer for a download. Enter a number from “0”
(disabled) to “15”. Factory default is “8”, so the NX-10 will answer after 8 rings.