Location
Term
Definition
2.6.2 Feature
Select
A menu entry that groups all optional features relating to
control panel system settings.
2.6.2.1 Inputs
A menu entry that groups options that enable features
relating to inputs.
2.6.2.1.1 On-board
zones
A menu option that disables the wired zones on the control
panel. This provides a completely wireless alarm system.
2.6.2.1.2 Box
Tamper
A menu option that enables the box tamper switch on the
control panel. The NX-10 has an input for a normally closed
tamper switch. When opened, a box tamper is reported as
an event.
2.6.2.1.3
ExitError limited to EE1
A menu option that limits the Exit Error to
Entry/Exit Delay 1.
2.6.2.1.4 Double
Pulse
A menu option that will allow two trips on the same cross-
zone to activate an alarm.
2.6.2.1.5
Force Default Zone Types
A menu option that uses the default zone types in the
country defaults for the selected country rather than
configured zone types.
2.6.2.1.6 A+B/Cross
Zone
When this feature is enabled, a first trigger from a zone will
send a BG report (unverified alarm or B-alarm) for that
zone. The B-alarm message will be written in the log. In
addition, a fix 30 minute timer will start. If a zone is
triggered for a 2nd time within the 30 minutes time frame,
this zone will send a BA report (burglary alarm or verified
alarm) to the monitoring station. If there is no 2nd zone
that was triggered within 30 minutes, the timer will be
cleared. A+B alarm reporting only works with intrusion
zone types using the SIA formats. When this feature is
enabled, the standard cross-zoning feature will be inactive.
2.6.2.1.7
Immediate Zone Restore
A menu option that sets the way zones are restored. When
it is On, the zones restore immediately. In this case all the
alarms and restores are sent as they occur even in case of
multiple alarms. When this option is Off, the zones restore
only when the siren is off or disarmed. In this case a second
or subsequent alarm will not be sent until the siren times
out.
2.6.2.2 Diagnostics
A menu entry that groups test options. These options
specify the tests that can be performed on the control
panel.
2.6.2.2.1
Batt Missing Test
A menu option that enables a test to determine whether
the battery is connected to the system. This test is usually
performed automatically when the system is first powered
up and periodically thereafter.
2.6.2.2.2
Dynamic Batt Test at Arming
A menu option that enables a dynamic battery test at
arming. This is an automatic test carried out by the control
panel at the moment of arming to ensure the battery is
working properly. The panel lowers the battery charging
voltage in order to draw current from the battery. If the
system is not armed between 00:01 and 23:59, the test is
performed at 00:00.
2.6.2.2.3
Manual Siren Test
A menu option that activates the siren test when the
LCD &
Self Test
command is selected from the user menu.