Table 34. NX-586E direct connect module serial connector
Sub
D9
D25
RXD
PIN 2
PIN 3
TXD
PIN 3
PIN 2
GND
PIN 5
PIN 7
7.
Connect the cable to the NX-586E direct connect module.
8.
Using stripped wires, connect the cable with alligator clips to a NX-10 panel as follows:
•
Red to POS
•
Black to COM
•
Green to DATA
Connecting the NX-586E to a PC and a panel
Connect the NX-586E direct connect module to the serial port of the PC and the panel as shown in
the previous section.
Figure 28. Connecting the NX-586E to a PC and a panel
NX-586
DATA
POS
COM
#
"
!
NX-10