NX-10 Installers manual
171
•
Values between 90 and 80: These are low values but the sensor will still work
properly.
•
Values between 80 and 50: These are normal working values for sensor located at a
longer distance from the receiver.
•
Values smaller than 50: Perfect conditions.
RSSI Values may change due to environmental circumstances, for example, additional furniture or
metal constructions. The following example tests the RSSI value of zone 2 on receiver 32.
1.
Navigate with the
½¾
keys to
RF Receivers>RF Receiver 32
and press
OK.
2.
Scroll to
RSSI RF Device> RF Sensors>RF Zone 2
and press
OK
.
3.
The RSSI value is displayed on the keypad.
The following example tests the RSSI value of the RF keypad 3 on receiver 32.
1.
Navigate with the
½¾
keys to
RF Receivers>RF Receiver 32
and press
OK.
2.
Scroll to
RSSI RF Device> RF Keypads>RF Keypad 3
and press
OK
.
3.
The RSSI value is displayed on the keypad.
The following example tests the RSSI value of the RF siren/IO module 2 on receiver 32.
1.
Navigate with the
½¾
keys to
RF Receivers>RF Receiver 32
and press
OK.
2.
Scroll to
RSSI RF Device> RF Sirens/IO>Siren/IO 2
and press
OK
.
3.
The RSSI value is displayed on the keypad.
Disabling wireless sensors
You can program a receiver to disable a wireless sensor. This does not remove the sensor
identification from the module’s memory. The wireless sensor can be reactivated later or a new
sensor can be learned into the zone. The following example removes sensor 10 learned in on receiver
32.
1.
Navigate with the
½¾
keys to
RF Receivers>RF Receiver 32
and press
OK
.
2.
Scroll to
Inputs>Sensor 10>Enabled>No
and press
OK
.
3.
The keypad beeps once to accept the change and returns to
Enabled
.
Glossary
Term
Definition
1 Pulse On
A menu entry that groups options enabling/disabling a single siren pulse at
arming or at the exit delay expiration. This options work for the following
output events only: Any siren, Burglary siren, Burglary alarm, 24 hour alarm.
Antipassivation
A menu entry that enables/disables the siren's battery antipassivation feature.
When enabled, a small current flows through IO module output 2 every 30
Содержание NX-10